Our exhaust air controls "lock" e.g. your cooker hood reliably until the corresponding window contact reports that you have opened the window.

This is prescribed in § 4 of the FeuVO (Fireplace Ordinance) as soon as you operate a combustion facility (i.e. a stove) in close proximity.

Therefore, your chimney sweep will also make you aware if you need an exhaust control system.

Conversely, the climate controls, which are also suitable for heat pumps, for example, switch. Because they turn off the connected device as soon as you open a window.

This helps save energy - so you don't heat your money out the window.

Exhaust air and air conditioning control overview

Exhaust air controls

radio

Radio exhaust air control FDS 100 DIBt

Item no.: 300268
155,00 
The transmitter of the FDS 100 set with DIBt approval monitors the window position and transmits the information by radio to a built-in receiver with a potential-free 5 A changeover relay. In this way, an exhaust air system can only be operated with a tilted or open window if it is ensured that sufficient fresh air flows into the room and thus no negative pressure is created that could draw dangerous and toxic carbon monoxide from a combustion site.

Radio exhaust air control FDS 200 DIBt

Item no.: 300462
149,95 
Possible applications
  • Fume cupboard control
  • Exhaust air control
  • Simple receiver installation in seconds
  • for trough fans is only the FDS 100 or KDS 110 suitable!
  The transmitter of the FDS 200 set with DIBt approval monitors the window position and transmits the information by radio to an intermediate plug receiver with a switched 5 A socket. In this way, an exhaust air system can only be operated with a tilted or open window if it is ensured that sufficient fresh air flows into the room and thus no negative pressure is created that could draw dangerous and toxic carbon monoxide from a combustion site.

Radio exhaust air control FDS 216

Item no.: 300460
175,00 
The transmitter of the FDS 216 set without DIBt approval monitors the window position and transmits the information by radio to an intermediate plug receiver with a switched 16 A socket. In this way, an exhaust air system can only be operated with a tilted or open window if it is ensured that sufficient fresh air flows into the room and thus no negative pressure is created that could draw dangerous and toxic carbon monoxide from a combustion site. Possible applications
  • Fume cupboard control
  • Exhaust air tumble dryer
  • Simple receiver installation in seconds

Radio exhaust air control FGS 170

Item no.: 300714
173,00 
The FGS 170 radio gas heater control system consists of a 230-volt transmitter, which interrogates the potential-free contact of a gas heater, and a 230-volt receiver, which converts the change of state of the gas heater into a changeover of the potential-free changeover relay. With this system, a bathroom fan, for example, can be switched off when the gas heater is ignited.

Radio receiver FDS 199

Item no.: 300601
82,00 
Additional receiver for the exhaust air controls FDS 100 and FDS 200

Radio receiver FDS 299

Item no.: 300602
87,00 
Additional receiver for the exhaust air controls FDS 100 and FDS 200

Radio receiver FGS 170-E

Item no.: 300701
85,00 
Additional receiver for the FGS 170 exhaust air controls  

Radio magnetic switch FDS 098

Item no.: 300098
79,90 
Additional transmitter for FDS 100/200/216, FKS 100/200

Cable

Cable exhaust control KDS 210 DIBt

Item no.: 300672
119,90 
The magnetic switch of the KDS 210 set with DIBt approval monitors the window position and transmits the information via a thin cable to an intermediate plug control unit with a switched 5 A socket. In this way, an exhaust air system can only be operated with a tilted or open window if it is ensured that sufficient fresh air flows into the room and thus no negative pressure is created that could draw dangerous and toxic carbon monoxide from a combustion site. Possible applications
  • Fume cupboard control
  • Exhaust air control
  • for trough fans is only KDS 110 suitable

Cable magnetic switch KMS 098K22

Item no.: 300743
19,90 
Additional magnetic switch for KDS 110/116/210 and KDT 210 The additional magnetic switch for a second (or more) window is equipped with 2 screw terminals and is mounted between the control unit and the original magnetic switch. The connection is made with a 2-wire LiYY control cable. The OR function is achieved, only one of the two windows must be open for an exhaust air control KDS / KDT to release the fan motor or an air conditioning control KKS to switch off the air conditioning.

Cable exhaust control KDS 116

Item no.: 300750
79,00 
Cable exhaust control with built-in unit! The magnetic switch of the KDS 116 without DIBt approval monitors the window position and transmits the information via a thin cable to a built-in control unit with potential-free 16 A changeover relay. For example, an exhaust air laundry dryer can only be operated with the window tilted or open if it is ensured that sufficient fresh air flows into the room and thus no negative pressure is created that could draw dangerous and toxic carbon monoxide from a combustion site. Possible applications
  • Fume cupboard control
  • Bathroom fan control
  • Exhaust air clothes dryer
 

Cable exhaust control KGS 116

Item no.: 300715
79,00 
The KGS 116 cable gas heater control unit interrogates the potential-free normally open contact of a gas heater and converts the change of state of the gas heater into a changeover of the potential-free changeover relay. With this system, e.g. a bathroom fan can be switched off when the gas heater is ignited.   Possible applications
  • Gas boiler in combination with bathroom fan

Cable exhaust control KDS 110 DIBt

Item no.: 300740
99,00 
The magnetic switch of the KDS 110 set with DIBt approval monitors the window position and transmits the information via a thin cable to a built-in control unit with a potential-free 5 A change-over relay. In this way, an exhaust air system can only be operated with a tilted or open window if it is ensured that sufficient fresh air flows into the room and thus no negative pressure is created that could draw dangerous and toxic carbon monoxide from a combustion site. Depending on the connection option (e.g. Miele PUR 98), the light of the bonnet can also be switched on independently of the window position.

Cable exhaust control with thermal switch KDT 210

Item no.: 300674
249,00 
This package without DIBt approval includes a classic cable exhaust air control set KDS 210 consisting of a window solenoid switch with intermediate plug control unit and an exhaust gas temperature monitor ATW 519 with integrated cable breakage protection for a free piece of stove pipe that is accessible at any time, with all components already pre-assembled. Due to the additional temperature switch, the exhaust air system can be operated independently of the window position as long as the furnace is cold; opening the window is only necessary when the furnace is in operation. Hint: Involve your chimney sweep in your planning before installation so that nothing stands in the way of acceptance afterwards. There are significant regional differences over which Elektrotechnik Schabus has no influence.  

Possible applications

  • Fume cupboard control
  • Exhaust air control

Exhaust gas temperature monitor

Exhaust gas temperature monitor ATW 519 40°C

Item no.: 201749
129,00 
The Cetrotec exhaust gas temperature monitor type 519 with 40°C switching point is type-tested by TÜV, approved for use in heat generating plants and is mounted with a flange on a free piece of stove pipe with a minimum diameter of 120 mm. Its normally closed contact can switch power, its normally open contact is only intended for control tasks, so it is technically suitable for bridging an exhaust air control when the furnace is cold or is used slightly modified as a control device for our cable exhaust air controls. Possible applications
  • Bivalent operation with gas or oil heating to lock it when the solid fuel boiler is in operation
  • Monitoring tasks to switch off the exhaust air system in rooms with open or closed fireplaces to prevent exhaust gases from being sucked back into the rooms when the fireplace is burning.
  • Other monitoring and control tasks such as controlling the storage tank charging pump
  • Indicator lamp for fuel boiler burnout
Hint: Involve your chimney sweep in your planning before ordering so that nothing stands in the way of acceptance afterwards. There are significant regional differences over which Elektrotechnik Schabus has no influence.

Flue gas temperature monitor ATW 519 - KDS 110/116

Item no.: 201753
138,99 
The Cetrotec flue gas temperature monitor type 519 with 40°C switching point and 10-k resistor is approved for use in heat generating plants and is mounted with a flange on a free piece of furnace pipe with a minimum diameter of 120 mm. Its normally open contact is only intended for control tasks and has been bridged by us with a 10 kOhm cable breakage protection resistor, therefore this version of the temperature monitor is only suitable as an optional accessory for our KDS cable exhaust air controls in order to enable an exhaust air system when the stove is cold without having to open a window each time as well, provided that the approval of the master chimney sweep is available, since an exhaust air control in combination with an exhaust gas temperature monitor does not have DIBt approval.

Exhaust gas temperature monitor ATW 519 50°C

Item no.: 201759
129,00 
The Cetrotec exhaust gas temperature monitor type 519 with 50°C switching point is type-tested by TÜV, approved for use in heat generating plants and is mounted with a flange on a free piece of stove pipe with a minimum diameter of 120 mm. Its normally closed contact can switch power, its normally open contact is only intended for control tasks, so it is technically suitable for bridging an exhaust air control when the furnace is cold or is used slightly modified as a control device for our cable exhaust air controls. Hint: Involve your chimney sweep in your planning before installation so that nothing stands in the way of acceptance afterwards. There are significant regional differences over which Elektrotechnik Schabus has no influence.

Possible applications

  • Bivalent operation with gas or oil heating to lock it when the solid fuel boiler is in operation
  • Monitoring tasks to switch off the exhaust air system in rooms with open or closed fireplaces to prevent exhaust gases from being sucked back into the rooms when the fireplace is burning.
  • Other monitoring and control tasks such as controlling the storage tank charging pump
  • Indicator lamp for fuel boiler burnout

Air flow monitor

Air flow monitor RLSW5

Item no.: 21006
389,00 
The air flow monitor is placed in the exhaust air flow of a cooker hood behind the grease filter and monitors whether the exhaust air really flows at the required and adjustable speed. If this is the case, a potential-free changeover relay is switched, which releases the gas supply for gastronomic gas hobs by means of a gas solenoid shut-off valve. The air flow monitor is the basis for the so-called "mutual interlocking of exhaust air and gas supply". Possible applications
  • Use in gastronomy
  • for mutual interlocking of the gas supply for ovens in combination with ventilation systems as well as extractor bonnets

Key switch

Item no.: 300776
159,00 
Key switch with make contact for surface mounting. The key can be removed in the centre position when the switch is on or off.

Comfort packages

Comfort package FTW 519 with FDS 100 set

Item no.: 300519
319,00 
This comfort package without DIBt approval includes a classic FDS 100 exhaust air control set consisting of a radio window switch with intermediate plug receiver and an FTW exhaust gas temperature monitor with integrated transmitter for long, completely free (not jacketed) stove pipes at a minimum height of 80 cm (measured from the top of the stove). This means that for very infrequently used furnaces, a window does not always have to be opened every time the exhaust air system is used.
Hint: Involve your chimney sweep in your planning before ordering so that nothing stands in the way of acceptance afterwards. There are significant regional differences over which Elektrotechnik Schabus has no influence.

FTW 519 Comfort package with FDS 200 set

Item no.: 300529
329,00 
This comfort package without DIBt approval includes a classic FDS 200 exhaust air control set consisting of a radio window switch with built-in receiver and an FTW exhaust gas temperature monitor with integrated transmitter for long, completely free (unjacketed) stovepipes at a minimum height of 80 cm (measured from the top edge of the stove). This means that for very rarely used furnaces, a window does not always have to be opened as well every time the exhaust air system is used.
Hint: Involve your chimney sweep in your planning before ordering so that nothing stands in the way of acceptance afterwards. There are significant regional differences over which Elektrotechnik Schabus has no influence.

Comfort package FDS 100 / FTX 519

Item no.: 300539
319,00 
This comfort package without DIBt approval includes a classic radio exhaust control set FDS 100 consisting of a window switch with built-in receiver and a radio exhaust temperature monitor FTX with remote transmitter for shorter or covered, but always freely accessible stovepipes. This means that for very rarely used stoves, a window does not always have to be opened every time the exhaust air system is used.
Hint: Involve your chimney sweep in your planning before installation so that nothing stands in the way of acceptance afterwards. There are significant regional differences, on which Elektrotechnik Schabus has no influence.

Comfort package FDS 200 / FTX 519

Item no.: 300549
329,00 
This comfort package without DIBt approval includes a classic FDS 200 extract air control set consisting of a radio window switch with intermediate plug receiver and an FTX flue gas temperature monitor with remote transmitter for shorter or covered but always freely accessible stovepipes. This means that for very rarely used stoves, a window does not always have to be opened every time the exhaust air system is used.

Supply air controls

Cable supply air control KZS 200

Item no.: 301745
135,01 
The intermediate plug of the cable supply air control KZS 200 is plugged in between the cooker hood and the socket and detects whether only the light of the hood or also the exhaust air motor is switched on by means of a consumption value adjustable from 5 to 250 watts. If the device detects a running motor, a supply air flap is opened via the line and also closed again after the exhaust air motor is switched off. The KZS 200 control unit is available for both variants of the Supply air dampers suitable for the slow but powerful Belimo motor of the airtight dampers as well as for the fast spring-return motor of the plastic dampers. Possible applications
  • Extractor fan control (independent of lighting)
  • Supply air dampers
Hint: Involve your chimney sweep in your planning before installation so that nothing stands in the way of acceptance afterwards. There are significant regional differences over which Elektrotechnik Schabus has no influence.
 

airtight supply air damper ⌀ 100 mm

Item no.: 201758
269,00 
The airtight electric supply air damper with a diameter of 100 mm and a high-torque condenser motor opens and closes each time within 150 seconds during open-close control or via 2-way control. The relatively long time is due to the slow-running motor, which has to press the EPDM sealing lip against the galvanized steel pipe with a lot of force. Such a damper is controlled, for example, by the KZS 200 supply air control, which automatically opens the damper when the exhaust air motor is switched on. Possible applications
  • Supply air control for incinerators
  • For controlling the air flow in ventilation and air-conditioning systems
  • Diameter: 100 mm
 

airtight supply air damper ⌀ 150 mm

Item no.: 201760
279,00 
The airtight electric supply air damper with a diameter of 150 mm and a high-torque condenser motor opens and closes each time within 150 seconds during open-close control or via 2-way control. The relatively long time is due to the slow-running motor, which has to press the EPDM sealing lip against the galvanized steel pipe with a lot of force. Such a damper is controlled, for example, by the KZS 200 supply air control, which automatically opens the damper when the exhaust air motor is switched on. Possible applications
  • Supply air control for incinerators
  • For controlling the air flow in ventilation and air-conditioning systems
  • Diameter: 150 mm
 

airtight supply air damper ⌀ 200 mm

Item no.: 201761
289,00 
The airtight electric supply air damper with a diameter of 150 mm and a high-torque condenser motor opens and closes each time within 150 seconds during open-close control or via 2-way control. The relatively long time is due to the slow-running motor, which has to press the EPDM sealing lip against the galvanized steel pipe with a lot of force. Such a damper is controlled, for example, by the KZS 200 supply air control, which automatically opens the damper when the exhaust air motor is switched on. Possible applications
  • Supply air control for incinerators
  • For controlling the air flow in ventilation and air-conditioning systems
  • Diameter: 200 mm
 

Supply air damper electric ⌀ 100 mm

Item no.: 201756
205,00 
The electric supply air damper with a diameter of 100 mm and a fast spring return motor opens within 8 seconds when the operating voltage is applied and closes, also braked by the spring gear, in about 8 seconds when the operating voltage is removed. Such a damper is controlled e.g. by the KZS 200 (301745) supply air control, which automatically opens the damper when the exhaust air motor is switched on. Possible applications
  • Supply air control for extractor bonnet
  • For controlling the air flow in ventilation and air-conditioning systems
  • Diameter: Ø100 mm
 

Supply air damper electric ⌀ 150 mm

Item no.: 201755
209,00 
The electric supply air damper with a diameter of 150 mm and a fast spring return motor opens within 8 seconds when the operating voltage is applied and closes, also braked by the spring gear, in about 8 seconds when the operating voltage is removed. Such a damper is controlled, for example, by the KZS 200 (301745) supply air control unit, which automatically opens the damper when the exhaust air motor is switched on. Possible applications
  • Supply air control for extractor bonnet
  • For controlling the air flow in ventilation and air-conditioning systems
 

Supply air damper electric ⌀ 200 mm

Item no.: 201752
215,01 
The electric supply air damper with a diameter of 200 mm and a fast spring return motor opens within 8 seconds when the operating voltage is applied and closes, also braked by the spring gear, in about 8 seconds when the operating voltage is removed. Such a damper is controlled, for example, by the KZS 200 (301745) supply air control unit, which automatically opens the damper when the exhaust air motor is switched on. Possible applications
  • Supply air control for extractor bonnet
  • For controlling the air flow in ventilation and air-conditioning systems
 

Differential pressure controller & necessary accessories

Differential pressure controller DS01 L

Item no.: 21000
1.190,00 
The differential pressure controller DS 01 is a safety device that enables the simultaneous operation of room-air dependent fireplaces for solid or liquid fuels with ventilation systems.

Possible applications

  • For mutual safety monitoring (including interlocking) of ovens in combination with ventilation and air-conditioning systems such as controlled ventilation and extraction systems and extractor bonnets
  • Ideal for the use of fireplaces (solid or liquid fuels) in low-energy or passive houses with ventilation systems (not suitable for open fireplaces or open operation).

Differential pressure controller DS01 M

Item no.: 21100
1.850,00 
Safety device that allows simultaneous operation of a room-air dependent fireplace with a wodtke pellet primary stove on a common chimney!

Pressure measuring adapter accessories DS01

Item no.: 21003
49,00 
Pressure measurement adapter Elbow fitting necessary for measuring the negative pressure in the exhaust pipe of the combustion site. Necessary accessories for differential pressure controller DS01

Pressure measuring tube accessories DS01 L

Item no.: 21004
25,00 
Connecting tube of pressure measuring adapter and silicone hose (Included in comfort package 21021) Necessary accessories for differential pressure controller DS01

DS-01 L Comfort package ventilation + stove

Item no.: 21021
1.850,00 
The DS 01 L Comfort package already contains all accessories together with the DS 01 L control unit that are absolutely necessary for technical operation. In addition to the control unit and 5 metres of silicone hose, it contains the temperature measuring adapter, the pressure measuring adapter and the pressure measuring tube, which is intended for connecting the hose to the pressure measuring adapter. This way, nothing important can be forgotten with only one item number.   Possible applications
  • For mutual safety monitoring (including interlocking) of ovens in combination with ventilation and air-conditioning systems such as controlled ventilation and extraction systems and extractor bonnets
  • Ideal for the use of fireplaces (solid or liquid fuels) in low-energy or passive houses with ventilation systems (not suitable for open fireplaces or open operation).

DS-01 L Comfort package ventilation + pellet primary stove

Item no.: 21022
1.850,00 
The differential pressure controller DS 01 is a safety device that enables the simultaneous operation of room-air dependent fireplaces for solid or liquid fuels with ventilation systems. Possible applications
  • for monitoring the simultaneous operation of controlled ventilation systems and wodtke pellet primary stoves
  • For mutual safety monitoring (including interlocking) of ovens in combination with ventilation and air-conditioning systems such as controlled ventilation and extraction systems and extractor bonnets
  • Ideal for the use of fireplaces (solid or liquid fuels) in low-energy or passive houses with ventilation systems (not suitable for open fireplaces or open operation).

DS-01 M Comfort Package Mixed Occupancy

Item no.: 21023
1.850,01 
Suitable for safety monitoring of the mixed occupancy of a chimney with a wodtke pellet primary stove and a commercially available, closed fireplace for solid fuels without fan in accordance with EN 13240, EN 13229 or EN 12815.

DS-01 M Comfort Package Multiple Occupancy

Item no.: 21024
2.499,00 
DS 01 M Comfort package for multiple use with 2 wodtke pellet primary stoves Suitable for safety monitoring of multiple occupancy of a chimney with two wodtke pellet primary stoves.

Rosette - ⌀ 130 mm black - Accessories DS01

Item no.: 21009
209,00 
Temperature and pressure measuring adapters are screwed into the stovepipe, very close to the transition to the brick chimney, the lines and hoses are flush-mounted, and the still openly visible technology is covered "suitable for living space" with the rosette.  

Rosette - ⌀ 130 mm silver gray - Accessories DS01

Item no.: 21010
209,00 
Temperature and pressure measuring adapters are screwed into the stovepipe, very close to the transition to the brick chimney, the lines and hoses are flush-mounted, and the still openly visible technology is covered "suitable for living space" with the rosette.  

Rosette - ⌀ 150 mm black - Accessories DS01

Item no.: 21011
199,00 
Temperature and pressure measuring adapters are screwed into the stovepipe, very close to the transition to the brick chimney, the lines and hoses are flush-mounted, and the still openly visible technology is covered "suitable for living space" with the rosette.

Rosette - ⌀ 150 mm silver gray - accessory DS01

Item no.: 21012
209,00 
Temperature and pressure measuring adapters are screwed into the stovepipe, very close to the transition to the brick chimney, the lines and hoses are flush-mounted, and the still openly visible technology is covered "suitable for living space" with the rosette.

Temperature measuring adapter accessories DS01

Item no.: 21001
169,00 
Necessary accessories for differential pressure controller DS01

Wall-mounted box Alu-Compound

Item no.: 21005
299,00 
Wall-mounting box with exclusive aluminum compound decor plate to accommodate the DS 01 for flush-mounting. Accessories for differential pressure controller DS01

Wall unit glass decor panel "white

Item no.: 21015
329,00 
Wall mounting box for flush mounting optinional accessories for differential pressure controller DS01 L and M

Climate controls

Radio climate control FKS 200

Item no.: 301462
168,98 
The transmitter of the FKS 200 set monitors the window position and transmits the information by radio to an adapter plug receiver with a switched 5 A socket. In this way, an air conditioner can be switched off automatically when a window is tilted or open, so that the outside air is not cooled and energy is wasted unnecessarily.  

Cable air-conditioning control KKS 210

Item no.: 301672
131,50 
The magnetic switch of the KKS 210 set monitors the window position and transmits the information via a thin wire to an intermediate plug control unit with a switched 5 A socket. In this way, an air conditioner can be switched off automatically when the window is tilted or open, so that the outside air is not cooled and energy is wasted unnecessarily.

Cable air-conditioning control KKS 116

Item no.: 301750
79,00 
  • KKS 116 Sets monitors the window position and transmits the information to a built-in control unit with potential-free 16 A changeover relay.
  • Thus, an air conditioner can be switched off automatically when the window is tilted or open.

Radio climate control FKS 100

Item no.: 301268
159,00 
Do not cool and heat out the window! The transmitter of the FKS 100 set monitors the window position and transmits the information by radio to a built-in receiver with potential-free 5 A changeover relay. In this way, an air conditioner can be switched off automatically when the window is tilted or open, so that the outside air is not cooled and energy is wasted unnecessarily.

matching accessories

Reed contact switch (NC contact) SHT 3002

Item no.: 300770
14,49 
The universally applicable magnetic switch with opener function can be used in all dry indoor spaces and, with its enclosed 4 spacer plates for height compensation, is ideal for mounting on door and window frames as well as door and window sashes. The 10-watt reed contact, which can be loaded with up to 500 mA at up to 20 volts, opens the contact when the magnet is very close to the switch. Without cable break protection, this switch cannot be used as an extension for Schabus exhaust air and air conditioning controls. Possible applications
  • Door / window switch with height compensation
  • Monitoring switches for alarm systems, limit switches, model making, etc.
  • LED interior lighting for wardrobe, like "fridge light" with opener contact

Reed contact switch (NO contact) SHT 3010

Item no.: 300761
25,00 
The universally applicable magnetic switch with normally open function can be used not only in dry interiors but also outdoors, i.e. on the outside of doors and windows. Possible applications
  • Door / window switch with height compensation
  • Can also be used outdoors
  • Monitoring switches for alarm systems, limit switches, model making, etc.
  • LED interior lighting for wardrobe, like "fridge light" with opener contact

Reed contact switch (NC contact) SHT 3020

Item no.: 300771
25,00 
This normally closed reed contact switch with magnet is specially designed for outdoor use.
Possible applications
  • Door/window switch
  • Monitoring switch
  • Limit switch
  • Model making
  • Cabinet lighting (LED)
  • uvm.

Reed contact switch (NO contact) SHT 3001

Item no.: 300760
12,50 
This normally open reed contact switch with magnet is universal for various applications. The kit is attached to a door or window by simple mounting. The supplied spacer plates can be used for height compensation. A standard cable (LIYY 2x0,14mm²) is connected to the terminal and can be inserted from both sides. This allows a series connection of several contact switches.
This reed contact switch (normally open) is universal for various applications applicable!
Possible applications
  • Door/window switch
  • Monitoring switch
  • Limit switch
  • Model making
  • uvm.

Battery CR2032 3V

Item no.: 200764
4,62 
Replacement battery for transmitters radio exhaust controls FDS 100/200

Battery CR2 3V

Item no.: 05.300504.0
6,50 
Replacement battery for the range of radio fume hood controls

Interference suppression capacitor

Item no.: 310268
29,00 
Accessories for FDS 100 and KDS 110/116

Reed contact switch (change-over contact) SHT 3030

Item no.: 300772
29,00 
This reed contact switch (change-over contact) is especially suitable for outdoor use!
Possible applications
  • Door/window switch
  • Monitoring switch
  • Limit switch
  • Model making
  • uvm.

Radio magnetic switch FDS 098 L

Item no.: 300198
79,00 
Additional transmitter for a second window can be combined with the FDS 100, FDS 200 and FDS 216 devices. At least one window must be open for the exhaust air system to be switched on. The serial number can be found on the type plate of the radio receiver or transmitter under the barcode field. Longlife additional transmitter for FDS 100/200/216

RAL painting for exhaust controls

Item no.: 09.67940.0
35,00 
WEEE NO.: EN91394868

Silicone hose

Item no.: 21002
19,90 
Possible applications
  • Accessories for DS 01 L (21000), GX-C300P (300256), GX-D500P (300263)
  • The Comfort package of the DS 01 L (21021) already includes 5 metres of hose
  • Sold by the metre, i.e. 1 order quantity = 1 metre

BBB 300 Potential-free contact | Light control

Item no.: 200603
69,00 
The BBB300 add-on module turns a switched socket (e.g. KDS 210 and FDS 200 exhaust air controls) into a potential-free contact that can be loaded with up to 5 amps. Ideal for using the control contacts of newer exhaust systems with existing socket exhaust control, but also to switch off only the motor and leave the lighting untouched. The switching behavior is: socket switched on = contact closed.

FAQ - Frequently asked questions

Changing the battery on the window contact

MODEL as of April 2023

Open the transmitter cover by inserting the enclosed screwdriver into the small groove on the short side of the housing and gently levering up the cover. You can change the battery without dismantling the transmitter from the window.

Lever the used button cell out of its holder with the enclosed screwdriver. Move the slotted screwdriver from above between the contact and the button cell and move the handle outwards; the button cell will pop out of its holder.

Insert the fresh CR 2032 / 3V button cell battery under the brass-colored battery hooks and then press the button cell down. Pay attention to the polarity: the labeling of the button cell with the + must point upwards and be legible.

Place the housing cover on the base housing until it clicks into place. The lid has a groove on one side, the housing base has a slot. The lid and base therefore only fit together in one direction.

MODEL until April 2023

First, the cover must be removed from the transmitter to the FDS 100 or FDS 200. To do this, press the cover together slightly on the right and left at the height of the LED and pull it off upwards:

To remove the old battery from the device, place the transmitter in front of you so that the antenna (black cable) is at the bottom right. Use the supplied screwdriver to drive vertically into the cavity between the battery and the battery holder and carefully pry the battery upwards.

The new battery is simply pressed into the battery holder from above.

Receiver in the hood rattles

You have already changed the battery, the small LED on the window contact transmitter also lights up green - but still the exhaust hood does not work and the receiver in the exhaust hood clatters?

Then it often helps to switch the fuse of the exhaust hood off and on again once. This hard reset often works wonders (similar to the PC).

after changing the battery, the hood no longer works

When changing the battery, make sure to insert the CR2032 button cell with the writing facing up.

If the battery is inserted the right way around and the exhaust hood still does not work, please try the following steps:

Close the window - wait briefly - open the window again - wait briefly again - then close the window again and open it again.

Now the transmitter (at the window) and receiver (at the exhaust hood) should have calibrated again and work properly

Shopping cart
Store
0 items Shopping cart
My account
Menu
Cookie Consent with Real Cookie Banner