The DS01 L differential pressure controller is a safety device that enables the simultaneous operation of room-air dependent fireplaces for solid fuels with ventilation systems (not suitable for open fireplaces or open mode of operation). The negative pressure in the connecting piece to the chimney compared to the surrounding room (= installation room or air compound) is permanently monitored during operation of the stove. This means that there can be no negative pressure in the room where the stove is installed/air connection, and thus no dangerous quantities of flue gas can escape via the stove into the room where the stove is installed. The integrated evaluation logic prevents an overly sensitive response in the event of wind pressure fluctuations or during a cold start of the fireplace. In addition, a plausibility check is performed. If the air pressure monitor switches off the connected system, sufficient fresh air supply must be provided to operate it again. Note: The DIBt approval refers exclusively to controlled residential ventilation systems, but not to extractor hoods, although the DS01L also works with these. Talk to your chimney sweep and include him in your planning so that nothing stands in the way of later approval. NEW: Automatic reset - automatic restart of the ventilation system after a malfunction.
Pressure measuring adapter (1) and temperature measuring adapter (2) provide the necessary data for the operation of this electronic safety device in buildings with controlled living space ventilation. The adapter rosette (3), optionally available in black and silver-grey, provides an attractive outer form - by simply sliding it over the flue pipe. The rosette is available to fit flue pipes with a diameter of 130 or 150 mm.
Scope of delivery
- Control unit DS01
- detailed operating and assembly instructions
Necessary accessories must be ordered as well! 1x temperature measuring adapter 1x pressure measuring adapter 1x pressure measuring tube 1x silicone hose - by the meter
Performance features
- 2 A potential-free change-over relay contact
- TÜV-tested with DIBt approval Z-85.1-2
- Safety device only becomes active when the fireplace is used (temperature monitoring of flue gas pipe).
Technical data
Operating voltage: | 230 V AC / 50 Hz |
Power consumption: | max. 3 VA |
Permissible pressure range: | -50 to +200 Pa |
Nominal measuring range: | -50 to + 50 Pa |
Overload capacity: | up to 1 kPa |
Switching relay: | max. 2 A / 250 V (AC) or 50 V (DC) |
Functional area: | 0° C / +60° C |
Protection class: | IP 54 |
Control unit (HxWxD): | 120 x 120 x 75 mm |
WEEE NO.: EN91394868
Reviews
There are no reviews yet.