Performance features
- 2 A potential-free change-over relay contact
- TÜV-tested with DIBt approval Z-85.1-2
- Safety device only becomes active when the fireplace is used (temperature monitoring of flue gas pipe).
Scope of delivery
- 21000 DS-01 Differential pressure controller
- 21001 Temperature measuring adapter
- 21003 Pressure measurement adapters
- 21004 Pressure measuring tube
- 5 metre 21002 Silicone hose
- detailed operating and assembly instructions
Technical data
Operating voltage: | 230 V AC / 50 Hz / max. 3 W |
Permissible pressure range: | -50 to +200 Pa, up to 1 kPa Overload |
Nominal measuring range: | -50 to + 50 Pa |
Switching relay: | max. 2 A / 250 V~ or 50 V= |
Functional area: | 0°C / +60°C |
Protection class_ | IP 54 |
Control unit (H x W x D): | 120 x 120 x 75 mm |
WEEE NO.: EN91394868
Reviews