The control unit is simply plugged between the socket and the mains plug of the cooker hood. The mains plug fuse prevents the appliance plug of the cooker hood from being reconnected. The control wires are installed on the window contact switch and the thermal switch. The set should be installed by a professional company. 6 meters each of control and silicone lines are enclosed. The lines must be mounted firmly as a surface-mounted line.
Second window
The system can be combined with another cable solenoid switch KMS 098K22 for a second window. At least one window must then be open so that the exhaust air system can be switched on while the furnace is in operation.
Lines are too short?
The cables pre-mounted on the KDT 210 can be extended with any 2-core cables up to 25 meters. Please call us, we can produce special lengths with 2-core cable for you. Cannot be ordered via wholesale!
Lines are to be laid in empty pipes?
To do this, the devices would have to be disconnected, which is not provided for in this variant. In this case, it is better to select the combination of KDS 110 and flue gas temperature monitor ATW 519here all terminals are open for freer and more flexible wiring.
Performance features
- All components TÜV tested
- Thermoswitch 40°C
- 2x 6 metre control and silicone cable pre-assembled
- Cable breakage protection
- for mounting on freely accessible piece of stovepipe
- Relay contact 5A with mains plug fuse
- 4 spacer plates for magnet (height adjustment window)
- Can be combined with second magnetic switch
- Simple installation due to surface-mounted cables
Scope of delivery
- Control unit with control cable 6m and silicone cable 6m
- Cable magnetic switch
- Thermoswitch
- 4x spacer plates for magnet
- Mounting material
- detailed assembly instructions
Technical data
Operating voltage: | 230 V AC / 50 Hz |
Switching capacity (max.): | 1150 VA (700 W) / 5 A (3 A) |
Control voltage: | 18 V |
Control line: | 6 m each / 2 x 0.14 mm² |
Functional area: | -15° C / +40° C |
Protection class: | IP 40 |
Control unit (HxWxD): | 121x57x46 mm |
Magnetic switch (HxWxD): | 55 x 31 x 18 mm |
Magnet (HxWxD): | 55 x 15 x 18 mm |
Spacer plate (HxWxD): | 55 x 15 x 5 mm |
KDT 210 combined with integrated switching contact on window | |
With the KDT 210, a cable breakage protection (10 KOhm resistor) is integrated in the supplied cable magnetic switch. If the KDT 210 is not used with the original cable magnetic switch, but with an integrated switching contact on the window, the following must be observed: In order to maintain the cable break protection, you must connect the supplied 10 KOhm resistor parallel to the normally open contact according to the connection example. |