- Easy installation with wall bracket
- optical warning, from 800 ppm yellow, from 1200 ppm red
- Acoustic warning only in the highest warning level from 2000 ppm onwards
- Detection of carbon dioxide (CO2) from stale air
- Bright, far visible light
- Internal infrared sensor
- Standard colour white
- Available in all RAL colours on request
Scope of delivery
- CO2 traffic light with 0.8 m cable and wall mounting set
- 12 V plug power supply unit with 1.5 m cable
- Operating instructions
Important information about all CO-2 traffic lights
Please do not unplug your traffic light overnight! The traffic light uses the nightly rest periods to calibrate itself properly - just like during regular, daily shock ventilation in the rooms. Therefore, please leave the traffic light permanently switched on, i.e. on, during operating and/or school hours. The traffic light memorizes the lowest CO2 concentration of the last 7 days and always resets itself to its theoretical zero point in this rhythm. For this auto-calibration, the weekly average is much more meaningful than a daily average. To save energy, the traffic light has a light sensor that darkens the LEDs after 10 minutes in absolute darkness, thus lowering the total power requirement.
That is why it is so important to supply the traffic lights with power even at night.
Only in case of school vacations / company vacations of more than 7 days, the traffic light can be taken off the network.
Operating voltage: | 12 V DC from enclosed plug-in power supply unit |
Supply cable traffic light / power supply unit: | approx. 80 cm / approx. 150 cm |
Protection class: | IP 20 |
Sensor type: | NDIR Infrared, internal |
Trigger concentrations: | approx. 800 ppm yellow / 1200 ppm red |
highest trigger concentration CO2: | approx. 2000 ppm |
Functional area sensor: | +5°C / +45°C |
Humidity (ambient): | 5-90 % RH (non-condensing) |
Illuminant: | long-life LEDs |
Dimensions (HxDxD): | 303 x 55 x 80 mm |
WEEE NO.: EN91394868