Home " Delivery program

73-144 of 204 results are displayed

Level indicator SET

Item no.: 300782
549,01 
Performance features
  • The digital tank display of the current content quantity is optionally in litres, in centimetres of filling level or as a percentage.
  • For various liquids: Heating oil, diesel, biodiesel, vegetable oil, palm oil, rapeseed oil, water, lubricating oils, AdBlue, etc.
  • Up to 2 m water column / oil tanks up to 2.5 m height

Anti-theft device for CO2 traffic lights

Item no.: 300948
13,23 
Anti-theft device for CO2 traffic lights Application area
  • for installation in public areas (e.g. schools, administrative buildings, etc.)
  • suitable for all SCHABUS CO2 traffic lights

Ball protection grid for CO2 traffic light

Item no.: 300947
89,00 
protects against hard hits from balls or similar in gyms and kindergartens Application area
  • Sports facilities
  • Gymnasiums
  • Kindergartens

Anti-theft device for plug-in devices

Item no.: 300946
13,23 
for use in public spaces with public traffic makes occasional pick-ups difficult

CO2 traffic light "customized

Item no.: 400370
358,02 
Reminds of regular draught ventilation in case of stale air
Possible applications
  • Monitoring of all dry indoor spaces where there are often / many people, e.g. gastronomy, etc.
  • Reliable reminder for regular draught ventilation

CO2 traffic light "Factory

Item no.: 400360
306,73 
Reminds of regular draught ventilation in case of stale air Warning levels:
  • at 1400 ppm CO2 on yellow
  • from 2000 ppm CO2 on red
  • from 2500 ppm CO2 on red flashing with alarm tone
Possible applications
  • Monitoring of open-plan offices, production facilities, workshops, etc.
  • for all rooms where people spend long periods of time on a regular basis
  • Reliable reminder for regular draught ventilation

CO2 traffic light "Medical

Item no.: 400350
306,73 
The CO2 traffic light "medical" with wall mount and plug-in power supply is our most sensitive version, which already switches to yellow at 800 ppm CO2, from 1200 ppm CO2 to red and from 2000 ppm CO2 to red flashing with alarm tone. It is therefore ideally suited for monitoring rooms in which many people with special physiological restrictions are often present, e.g. waiting rooms in doctors' surgeries or senior residences.   Possible applications
  • Surveillance of doctors' surgeries, hospitals, old people's homes, etc.
  • for all rooms where people spend long periods of time on a regular basis
  • Reliable reminder for regular draught ventilation

Dust Filter Replacement for GX-C300P

Item no.: 300259
29,90 
Replacement dust filter for CO alarm GX-C300P!

PROF. GAS ALARM GX-C300S

Item no.: 300265
389,00 
The professional carbon monoxide warning device with internal CO sensor, whose measuring cell, evaluation electronics and software have been tested by TÜV Süd according to the standard, is here equipped with an additional external city and natural gas sensor, which makes the entire system the perfect warning device for the boiler room in which a gas heating system or boiler is installed. The alarm relay, which is energised in monitoring mode, drops out when gas is detected (methane, butane, propane, ethanol) or when the CO concentration specified by the standard is exceeded, and can thus switch off the heating system with its solenoid shut-off valve in the event of danger to reliably prevent further inflow of toxic or flammable gases.

GAS ALARM GX-B1pro

Item no.: 300924
109,00 
The socket gas warning device with internal sensor for town gas and natural gas is plugged into an upper (natural gas / methane) or lower (liquid gas / butane, propane) socket depending on the gas, is ready for operation after 3 minutes preheating time and warns already far below dangerous gas concentrations with a loud alarm tone and red flashing LED. Possible applications
  • Monitoring of gas heating or gas cooker / detection of town, natural and liquid gases
  • Monitoring of the heating and utility rooms
  • Storage of liquid gas cylinders or camping gas
  • Air conditioners / coolants

Water sensor SHT 5009 for floor mounting

Item no.: 300720
44,99 
Accessories for water detector The water sensor SHT 5009 with three plate electrodes is suitable for floor mounting on soft floors such as parquet, laminate, but also carpets or linoleum floors. With its 2-wire cable it is directly ready for connection to the Schabus water detectors SHT 5000 and SHT 5001, as well as to the level controller SHT 5002 as overflow detector. The middle drill hole is reinforced with aluminum, so depending on the type of mounting desired, a thread can also be cut.

Water sensor SHT 5600 with 3 contacts

Item no.: 300753
35,01 
Accessories for water detectors
The SHT 5600 water sensor is identical in construction to the SHT 5006 standard water sensor, except that with the SHT 5600 an additional third contact has been inserted in the gap between the two ground contacts. This makes it possible, in conjunction with the SHT 5001 water detector, to distinguish between the messages "soil moisture" and "water rising further" and to take different measures, since with the SHT 5001 a separate relay is switched for each of the two states.

PROF. CO ALARM GX-C300P

Item no.: 300256
399,00 
Professional carbon monoxide warning device for permanent installation with warning levels and alarm delay times as specified in the DIN EN 50291 standard and suction device by means of a silicone hose to monitor thermally demanding rooms (e.g. gas-operated sauna). Display of the exact measured CO concentrations in ppm on an illuminated plain text display. In the event of an alarm and technical faults detected by the unit itself, a potential-free changeover relay switches in each case, e.g. to activate forced ventilation or to inform the BMS. The internal electrochemical sensor has a service life of 6 to 10 years, depending on the ambient conditions, and can easily be replaced by Elektrotechnik Schabus at the factory.

PROFI CO ALARM GX-C300

Item no.: 300255
299,00 
Professional carbon monoxide warning device for fixed installation with warning levels and alarm delay times as specified in the DIN EN 50291 standard. Display of the exact measured CO concentrations in ppm on an illuminated plain text display. In case of alarm and in case of technical faults detected by the device itself, one potential-free change-over relay each switches to activate e.g. forced ventilation or to inform the BMS. The internal electrochemical sensor has a service life of 6 to 10 years, depending on the ambient conditions, and can easily be replaced by Elektrotechnik Schabus at the factory.

SHT 8080 active mini float switch

Item no.: 200363
88,99 
for direct connection to logic circuits

Active water sensor SHT 8800

Item no.: 200362
74,99 
for analogue inputs in smarthome, GLT, etc.

SHT 8060 active mini float switch

Item no.: 200361
58,99 
for direct connection to logic circuits

GAS ALARM GX-D2

Item no.: 300252
139,00 
The plug-in CO2 warning device with external sensor for carbon dioxide is simply plugged into a socket and the sensor is placed in an upper (more tolerant) or lower (more sensitive) position depending on the desired sensitivity. It is ready for operation after 3 minutes of preheating time and warns when half the MAC (2500 ppm) is reached with a loud alarm tone and red flashing LED.

Active water sensor SHT 8815 for ext. control units

Item no.: 200370
69,00 
Accessories for PLC, smarthome, ... Digital inputs with int. pull-up/pull-down resistor

GAS ALARM GX-D33

Item no.: 300257
179,50 
  • CO2 warning device for tea kitchens
  • according to DIN6653-2
The GX-D33 with internal sensor for carbon dioxide from pressurized CO2 bottles is plugged into one of the lower sockets located near the CO2 bottles to be monitored, is ready for operation after 3 minutes of preheating time and warns when 3.0%vol. CO2 is reached with a loud alarm sound and red flashing LED. It is the easiest to use CO2 detector for water bubblers with large CO2 bottles in small rooms.
DIN-EN 6653-2 with exceptions

CO2 ALARM GX-D1

Item no.: 300251
139,00 
The plug-in CO2 warning device with internal sensor for carbon dioxide is plugged into an upper (tolerant) or lower (sensitive) socket depending on the desired sensitivity, is ready for operation after 3 minutes preheating time and warns when half the MAC (2500 ppm) is reached with a loud alarm tone and red flashing LED.
Possible applications
  • Monitoring of medical practices, waiting rooms, open-plan offices, workshops, etc.
  • for all rooms where people spend long periods of time on a regular basis
  • by the exclus. acoust. Warning ideal for waiting rooms or the like where a visual warning could irritate
  • Reliable reminder to air regularly

Gas sensor GX-CFC for refrigerant

Item no.: 200901
119,00 
External refrigerant sensor for GX-A1+ or GX-HS warning devices, detects fluorinated hydrocarbons (HFC: R-22, R-32, R-410a, R-1234yf, ...) from leaking fittings of refrigeration, air conditioning and heat pump systems.

Flue gas temperature monitor ATW 519 - KDS 110/116

Item no.: 201753
138,99 
The Cetrotec flue gas temperature monitor type 519 with 40°C switching point and 10-k resistor is approved for use in heat generating plants and is mounted with a flange on a free piece of furnace pipe with a minimum diameter of 120 mm. Its normally open contact is only intended for control tasks and has been bridged by us with a 10 kOhm cable breakage protection resistor, therefore this version of the temperature monitor is only suitable as an optional accessory for our KDS cable exhaust air controls in order to enable an exhaust air system when the stove is cold without having to open a window each time as well, provided that the approval of the master chimney sweep is available, since an exhaust air control in combination with an exhaust gas temperature monitor does not have DIBt approval.

CO GAS ALARM GX-C1pro

Item no.: 300783
109,00 
The socket carbon monoxide warning device with internal electrochemical CO sensor is plugged into a medium-sized socket, is ready for operation after 5 minutes initialisation time and warns of excessive CO concentrations strictly according to the specifications of DIN EN 50291 for carbon monoxide in living spaces with a loud alarm tone and red flashing LED. The sensor, the evaluation, the measuring cell with its calibration as well as the software developed by Elektrotechnik Schabus were subjected to a full test at TÜV Süd according to DIN EN 50291, safety and stability were certified for the system. Possible applications
  • Monitoring for carbon monoxide leakage at combustion sites in flats, houses, shops, small businesses, cafés, low-dust workshops
  • Monitoring of all gas-fired installations
  • For gas heaters, gas heating, gas cookers, gas ovens, but also oil heaters and open fires, can also be used in bathrooms and other damp rooms, as long as moisture does not condense.
  • Designed for years of continuous operation
 

GAS ALARM GX-B2pro

Item no.: 300926
119,00 
The socket gas warning device with external sensor for town gas and natural gas is plugged into a socket and the sensor is set to an upper (natural gas / methane) or lower (liquid gas / butane, propane) position depending on the gas. The warning device is ready for operation after 3 minutes of preheating time and warns already far below dangerous gas concentrations with a loud alarm tone and red flashing LED. Possible applications
  • Monitoring of gas heating or gas cooker / detection of town, natural and liquid gases
  • Monitoring of the heating and utility rooms
  • Storage of liquid gas cylinders or camping gas
  • Air conditioners / coolants
 

CO ALARM GX-C3pro

Item no.: 300229
179,00 
The socket CO warning device with external sensor for carbon monoxide is plugged into a socket and the sensor is placed at average nose level. The warning device is ready for operation after 5 minutes and warns with the alarm thresholds specified in DIN standard 50291 with an alarm tone and a red flashing LED. In the event of an alarm, the device connected to the GX-C3pro, e.g. a gas heater, is also reliably switched off, whereby the device remains switched off until the user has ensured that his ventilation measures have had an effect and he resets the device by briefly unplugging it and plugging it back into the socket. Possible applications
  • Monitoring in case of leakage of carbon monoxide from all heat generating equipment in apartments, houses, stores, ...
  • Monitoring of all gas-operated systems and safety shutdown in the event of elevated CO levels
  • for gas heaters, gas heating, gas cookers, gas furnaces, oil heating and any combustion facility with supply
  • Can also be used in the bathroom and other damp rooms as long as moisture does not condense
  • Designed for years of continuous operation

Radio magnetic switch FDS 098 L

Item no.: 300198
79,00 
Additional transmitter for a second window can be combined with the FDS 100, FDS 200 and FDS 216 devices. At least one window must be open for the exhaust air system to be switched on. The serial number can be found on the type plate of the radio receiver or transmitter under the barcode field. Longlife additional transmitter for FDS 100/200/216

Gas sensor GX-DS Carbon dioxide

Item no.: 200884
179,00 
External CO2 sensor for GX-A1+ or GX-HS warning devices, detects CO2 from used air or CO2 exhaled by humans, as a timely reminder to ventilate at about half the TLV (2500 ppm).

Dirt trap accessories for mini float switches

Item no.: 300320
35,89 
Dirt trap Protector stainless steel incl. V2A mounting bracket Application area
  • Outdoor mini float switch and sensors
  • Floodplain
  • Ponds
  • Rain cisterns
  • against high dirt input (leaves, branches, grass, etc.)
  • Protection against small animals (frogs, snails, mice, etc.)

Comfort package FDS 200 / FTX 519

Item no.: 300549
329,00 
This comfort package without DIBt approval includes a classic FDS 200 extract air control set consisting of a radio window switch with intermediate plug receiver and an FTX flue gas temperature monitor with remote transmitter for shorter or covered but always freely accessible stovepipes. This means that for very rarely used stoves, a window does not always have to be opened every time the exhaust air system is used.

Aqua Scanner SHT 5020

Item no.: 300746
109,00 
The Aqua Scanner SHT 5020 is a 2 meter long sensor (extendable on request), sensitive to single drops of water along its entire length. The mechanically strong cable, resistant to corrosion and abrasion, consists of two sensor wires embedded in a fluoropolymer carrier rod. Due to the robust cable construction with conductive polymer technology and fluoropolymer construction detection, no metal is exposed. For cleaning, you can wipe it with a clean damp cloth. For connection to the Schabus water detectors is suitable only a LiYY control line with 2x 0.14mm², which can be ordered separately.

Possible applications

  • Accessories for SCHABUS water detectors SHT 5000, 5001 and 5002
  • 100% made in Germany
  • for laying under kitchen and bathroom furniture
  • under aquariums
  • under other devices, where water can leak over a wide area
  • under pipes, tubs, tanks ...
  • for indoor projects such as data centers / control rooms / HVAC / IOT
 

Comfort package FDS 100 / FTX 519

Item no.: 300539
319,00 
This comfort package without DIBt approval includes a classic radio exhaust control set FDS 100 consisting of a window switch with built-in receiver and a radio exhaust temperature monitor FTX with remote transmitter for shorter or covered, but always freely accessible stovepipes. This means that for very rarely used stoves, a window does not always have to be opened every time the exhaust air system is used.
Hint: Involve your chimney sweep in your planning before installation so that nothing stands in the way of acceptance afterwards. There are significant regional differences, on which Elektrotechnik Schabus has no influence.

Water sensor SHT 5007 UV-stabilised

Item no.: 300754
49,91 
Accessories for water detector The water sensor SHT 5007 with 2 nickel-plated brass contacts and 6 meter cable is identical in construction to the SHT 5006 water sensor, except that here a particularly UV-stable plastic is used for overmolding, which prevents the sensor from becoming porous so quickly in outdoor areas and regular exposure to sunlight. The SHT 5007 sensor for connection to all Schabus water detectors is only suitable for regularly dry environments, ideal for detecting creeping moisture on floors and surfaces, but rather unsuitable for detecting water levels in shafts, tanks and other containers with regularly damp environments.

GAS ALARM GX-CO-12

Item no.: 300712
129,00 
Areas of application
  • mobile use in camping vehicles and on ships
  • Camper, caravan
  • other recreational vehicles with gas cooking and cooling facilities
  • boiler room with gas heating or boiler
The CO detector, which has been fully tested by TÜV Süd according to DIN EN 50291, can be used both as a mobile device in your recreational vehicle (e.g. camper van) and as a stationary device at home. For mobile use, a cable for connection to the 12V or 24V battery is included, for operation at home, you will receive a plug-in power supply unit with matching RJ plug, so that alternating operation is also possible and the GX-CO-12 always ensures your safety: at home and on the road.   For installation in gas boilers from Viessmann we recommend the articles 7639852 or 7549937. Be sure to check the nameplate on the back to find the sensor that is right for you.

Gas sensor GX-CO2-25

Item no.: 200989
239,00 
External, active CO2 sensor with its own alarm, LEDs and test button, for connection to the warning devices GX-A1+ or GX-HS, detects CO2 from used air or CO2 exhaled by people, as a timely reminder to ventilate at about half the MAC (2500 ppm).
Performance features
  • External sensor for the gas detectors GX-A1 and GX-HS
  • Mains operation also possible without warning device
  • Detection of carbon dioxide(CO2): Reminder to ventilate regularly

Water sensor SHT 5800 for edge and floor mounting

Item no.: 300758
37,00 
Accessories for water detector The SHT 5800 water sensor with two contacts, completely handcrafted and suitable as an accessory for all Schabus water detectors, has stainless steel contacts and a hole reinforced with aluminum for mounting and is ideal for detecting damp floors or creeping soil moisture in regularly dry environments.

Water sensor SHT 5008 for floor mounting

Item no.: 300719
39,00 
The water sensor SHT 5008 with three contacts is suitable for floor mounting on hard floors such as screed, concrete, but also plastic (GRP) or tarred floors. With its 3-wire cable, the redundancy function or the differentiation between standing and rising water can be realized with the water detector SHT 5001, but by combining two cables, the SHT 5008 can also be easily operated on any other Schabus water detector as a floor sensor in a more stable design.

Alarm Controller Ei450

Item no.: 200723
95,00 
Radio alarm controller for smoke detectors and heat detectors and CO detectors! Radio remote control of all CO, smoke and heat detectors from EiElectronics combined in a radio network, locating the triggering detector, common testing, muting and saving the last alarm triggers. Incl. 10-year lithium battery and practical wall bracket.

Radio module Ei200MRF

Item no.: 200722
49,00 
Radio module Ei200MRF for Ei208iW  

10-Jahres-Funk-CO-Melder Ei208iW

Item no.: 200720
49,00 
Radio CO detector with 10-year lithium battery operation and audio
  • Surveillance of seminar rooms, classrooms, lecture halls, kindergartens
  • for all rooms where people spend long periods of time on a regular basis
  • Reliable reminder for regular draught ventilation
 

Radio module Ei600MRF

Item no.: 200818
72,00 
Radio module Ei600MRF for Ei650iW and Ei603TYC
  • with detailed operating and assembly instructions
 

GX-CO2-30 Carbon dioxide gas sensor

Item no.: 300315
239,00 
Ext. CO2 sensor for carbon dioxide - from technical equipment The external CO2 sensor with its own alarm transmitter, status LEDs and test button is optimized as an accessory for the SCHABUS gas warning devices GX-HS and GX-A1+ is oriented with its warning levels and protection class IP54 to the beverage dispensing system regulation. DIN-EN 6653-2 with exceptions

Cable exhaust control with thermal switch KDT 210

Item no.: 300674
249,00 
This package without DIBt approval includes a classic cable exhaust air control set KDS 210 consisting of a window solenoid switch with intermediate plug control unit and an exhaust gas temperature monitor ATW 519 with integrated cable breakage protection for a free piece of stove pipe that is accessible at any time, with all components already pre-assembled. Due to the additional temperature switch, the exhaust air system can be operated independently of the window position as long as the furnace is cold; opening the window is only necessary when the furnace is in operation. Hint: Involve your chimney sweep in your planning before installation so that nothing stands in the way of acceptance afterwards. There are significant regional differences over which Elektrotechnik Schabus has no influence.  

Possible applications

  • Fume cupboard control
  • Exhaust air control

DS-01 M Comfort Package Multiple Occupancy

Item no.: 21024
2.499,00 
DS 01 M Comfort package for multiple use with 2 wodtke pellet primary stoves Suitable for safety monitoring of multiple occupancy of a chimney with two wodtke pellet primary stoves.

DS-01 M Comfort Package Mixed Occupancy

Item no.: 21023
1.850,01 
Suitable for safety monitoring of the mixed occupancy of a chimney with a wodtke pellet primary stove and a commercially available, closed fireplace for solid fuels without fan in accordance with EN 13240, EN 13229 or EN 12815.

DS-01 L Comfort package ventilation + pellet primary stove

Item no.: 21022
1.850,00 
The differential pressure controller DS 01 is a safety device that enables the simultaneous operation of room-air dependent fireplaces for solid or liquid fuels with ventilation systems. Possible applications
  • for monitoring the simultaneous operation of controlled ventilation systems and wodtke pellet primary stoves
  • For mutual safety monitoring (including interlocking) of ovens in combination with ventilation and air-conditioning systems such as controlled ventilation and extraction systems and extractor bonnets
  • Ideal for the use of fireplaces (solid or liquid fuels) in low-energy or passive houses with ventilation systems (not suitable for open fireplaces or open operation).

Differential pressure controller DS01 M

Item no.: 21100
1.850,00 
Safety device that allows simultaneous operation of a room-air dependent fireplace with a wodtke pellet primary stove on a common chimney!

Wall unit glass decor panel "white

Item no.: 21015
329,00 
Wall mounting box for flush mounting optinional accessories for differential pressure controller DS01 L and M

Suspended float switch plastic

Item no.: 200950
59,00 
Suspended float switch with weight and PG gland for hanging on cable, for drums, sumps and tanks with horizontal lid  

EMY motoryoke SET PSU 200 Focus

Item no.: 400610
2.284,80 
Complete set consisting of all required individual components, as an equipment carrier system. For a detailed description of the individual elements, please refer to their item descriptions. Motoryoke

Special connection cable 4-core 5 metres

Item no.: 21013
39,90 
5 meter 4-core special connection cable for wodtke pellet primary stoves, for wiring the components including a strain relief with locknut (M16 x 1.5

DS-01 L Comfort package ventilation + stove

Item no.: 21021
1.850,00 
The DS 01 L Comfort package already contains all accessories together with the DS 01 L control unit that are absolutely necessary for technical operation. In addition to the control unit and 5 metres of silicone hose, it contains the temperature measuring adapter, the pressure measuring adapter and the pressure measuring tube, which is intended for connecting the hose to the pressure measuring adapter. This way, nothing important can be forgotten with only one item number.   Possible applications
  • For mutual safety monitoring (including interlocking) of ovens in combination with ventilation and air-conditioning systems such as controlled ventilation and extraction systems and extractor bonnets
  • Ideal for the use of fireplaces (solid or liquid fuels) in low-energy or passive houses with ventilation systems (not suitable for open fireplaces or open operation).

FTW 519 Comfort package with FDS 200 set

Item no.: 300529
329,00 
This comfort package without DIBt approval includes a classic FDS 200 exhaust air control set consisting of a radio window switch with built-in receiver and an FTW exhaust gas temperature monitor with integrated transmitter for long, completely free (unjacketed) stovepipes at a minimum height of 80 cm (measured from the top edge of the stove). This means that for very rarely used furnaces, a window does not always have to be opened as well every time the exhaust air system is used.
Hint: Involve your chimney sweep in your planning before ordering so that nothing stands in the way of acceptance afterwards. There are significant regional differences over which Elektrotechnik Schabus has no influence.

Comfort package FTW 519 with FDS 100 set

Item no.: 300519
319,00 
This comfort package without DIBt approval includes a classic FDS 100 exhaust air control set consisting of a radio window switch with intermediate plug receiver and an FTW exhaust gas temperature monitor with integrated transmitter for long, completely free (not jacketed) stove pipes at a minimum height of 80 cm (measured from the top of the stove). This means that for very infrequently used furnaces, a window does not always have to be opened every time the exhaust air system is used.
Hint: Involve your chimney sweep in your planning before ordering so that nothing stands in the way of acceptance afterwards. There are significant regional differences over which Elektrotechnik Schabus has no influence.

Folding float switch plastic

Item no.: 200949
19,90 
Hinged float switch made of plastic, normally open or normally closed function freely selectable by 180 ° rotation Possible applications
  • Tanks, cisterns
  • Pump sump
  • Water, fuel oil, vegetable oil, lubricating oils, etc.

Reed contact switch (change-over contact) SHT 3030

Item no.: 300772
29,00 
This reed contact switch (change-over contact) is especially suitable for outdoor use!
Possible applications
  • Door/window switch
  • Monitoring switch
  • Limit switch
  • Model making
  • uvm.

Water detector SHT 5002

Item no.: 300749
109,00 
The SHT 5002 water detector for top-hat rail mounting in the fuse box or small distribution board is designed as a level controller and has 2 different detection lines. Detection line 1 is the actual level controller, which receives the functions "Fill" or "Drain" by means of a wire jumper and switches its potential-free 5 A changeover relay depending on a lower and an upper level, each of which is defined by a mini float switch. Detection line 2 works like a simple water detector and is called "overflow detector" here, i.e. as soon as water is detected by a sensor or mini-float switch, the second relay of the SHT 5002 switches over.

airtight supply air damper ⌀ 100 mm

Item no.: 201758
269,00 
The airtight electric supply air damper with a diameter of 100 mm and a high-torque condenser motor opens and closes each time within 150 seconds during open-close control or via 2-way control. The relatively long time is due to the slow-running motor, which has to press the EPDM sealing lip against the galvanized steel pipe with a lot of force. Such a damper is controlled, for example, by the KZS 200 supply air control, which automatically opens the damper when the exhaust air motor is switched on. Possible applications
  • Supply air control for incinerators
  • For controlling the air flow in ventilation and air-conditioning systems
  • Diameter: 100 mm
 

Water detector SHT 228

Item no.: 300219
99,00 
The water detector for pump control! The SHT 228 socket water detector functions as a pump control. If a certain water level is detected with the mini float switch, the socket switches on the connected pump and in contrast to the SHT 227, the SHT 228 does not sound an alarm. After the water level drops below the specified level, the pump continues to run for an adjustable run-on time of 0 to 100 seconds and is then switched off. Possible applications
  • Water ingress
  • Pump sump
  • Cistern monitoring
  • Also suitable for other liquids (e.g. heating oil, diesel, vegetable oil, lubricating oils, etc.)

Water detector SHT 218

Item no.: 300218
109,00 
The SHT 218 socket water detector functions as a pump control. If soil moisture is detected with the sensor, the socket switches on the connected pump and the LED visually indicates the water ingress. After the sensor has dried, the pump continues to run for an adjustable follow-up time of 0 to 100 seconds and is then switched off.

Radio receiver FGS 170-E

Item no.: 300701
85,00 
Additional receiver for the FGS 170 exhaust air controls  

Radio receiver FDS 299

Item no.: 300602
87,00 
Additional receiver for the exhaust air controls FDS 100 and FDS 200

Radio receiver FDS 199

Item no.: 300601
82,00 
Additional receiver for the exhaust air controls FDS 100 and FDS 200

Weekly timer top-hat rail electronic

Item no.: 300400
39,00 
Timer for max. 16 A consumer with top-hat rail housing for panel mounting

EYE Couplier clamp 50 mm

Item no.: 400336
58,31 
Truss pick-up TÜV tested for pipes with diameter of 48-51 mm. Technical data load according to BGV C1: 100 kg tensile load: max.

TV peg 28 mm

Item no.: 400335
47,48 
WEEE NO.: EN91394868

Rosette - ⌀ 150 mm silver gray - accessory DS01

Item no.: 21012
209,00 
Temperature and pressure measuring adapters are screwed into the stovepipe, very close to the transition to the brick chimney, the lines and hoses are flush-mounted, and the still openly visible technology is covered "suitable for living space" with the rosette.

Supply air damper electric ⌀ 100 mm

Item no.: 201756
205,00 
The electric supply air damper with a diameter of 100 mm and a fast spring return motor opens within 8 seconds when the operating voltage is applied and closes, also braked by the spring gear, in about 8 seconds when the operating voltage is removed. Such a damper is controlled e.g. by the KZS 200 (301745) supply air control, which automatically opens the damper when the exhaust air motor is switched on. Possible applications
  • Supply air control for extractor bonnet
  • For controlling the air flow in ventilation and air-conditioning systems
  • Diameter: Ø100 mm
 

Interference suppression capacitor

Item no.: 310268
29,00 
Accessories for FDS 100 and KDS 110/116

Cable exhaust control KDS 110 DIBt

Item no.: 300740
99,00 
The magnetic switch of the KDS 110 set with DIBt approval monitors the window position and transmits the information via a thin cable to a built-in control unit with a potential-free 5 A change-over relay. In this way, an exhaust air system can only be operated with a tilted or open window if it is ensured that sufficient fresh air flows into the room and thus no negative pressure is created that could draw dangerous and toxic carbon monoxide from a combustion site. Depending on the connection option (e.g. Miele PUR 98), the light of the bonnet can also be switched on independently of the window position.

Radio magnetic switch FDS 098

Item no.: 300098
79,90 
Additional transmitter for FDS 100/200/216, FKS 100/200