GX-D500P
Item no.: 300263
Possible applications
- Dry ice processing/storage
- Beverage dispensing systems and greenhouses
- Meat and sausage cooling
- according to DIN 6653-2
- Automatic forced ventilation
- Rooms with very hot, cold, humid or dusty air or in ventilation systems with draughts
Radio exhaust air control FDS 216
Item no.: 300460
The transmitter of the FDS 216 set without DIBt approval monitors the window position and transmits the information by radio to an intermediate plug receiver with a switched 16 A socket. In this way, an exhaust air system can only be operated with a tilted or open window if it is ensured that sufficient fresh air flows into the room and thus no negative pressure is created that could draw dangerous and toxic carbon monoxide from a combustion site.
Possible applications
- Fume cupboard control
- Exhaust air tumble dryer
- Simple receiver installation in seconds
Silicone hose
Item no.: 21002GAS ALARM SET GX-A1+CO
Item no.: 300266
We have designed the GX-A1+CO set in such a way that it is possible to equip a professional carbon monoxide warning device with an external sensor, e.g. to position the warning device in front of the room to be monitored and the sensor in the room to be monitored in order to see from the outside whether the room is safe to enter.
The carbon monoxide concentration is evaluated and displayed with ppm accuracy. In the event of an alarm, a potential-free changeover relay switches and another relay switches in the event of technical faults detected by the warning device itself, such as a cable break or sensor failure, in order to inform the building control system.
Possible applications
- Carbon monoxide CO from incomplete combustion
- open fireplace, gas stoves, Swedish stoves
- Open fire, barbecue facilities, pellet bunker
Ball protection grid for CO2 traffic light
Item no.: 300947Cable supply air control KZS 200
Item no.: 301745
The intermediate plug of the cable supply air control KZS 200 is plugged in between the cooker hood and the socket and detects whether only the light of the hood or also the exhaust air motor is switched on by means of a consumption value adjustable from 5 to 250 watts. If the device detects a running motor, a supply air flap is opened via the line and also closed again after the exhaust air motor is switched off. The KZS 200 control unit is available for both variants of the Supply air dampers suitable for the slow but powerful Belimo motor of the airtight dampers as well as for the fast spring-return motor of the plastic dampers.
Possible applications
Hint:
Involve your chimney sweep in your planning before installation so that nothing stands in the way of acceptance afterwards. There are significant regional differences over which Elektrotechnik Schabus has no influence.
- Extractor fan control (independent of lighting)
- Supply air dampers
WWD 200 Smart Home Adapter
Item no.: 200200Starting current limiter ASB 120 3500W/16A
Item no.: 300118
The ASB 120 starting current limiter limits the current of a machine starting in no-load operation the machine connection power for about 700 milliseconds immediately after it is switched on and then switches the current fully through in order to effectively prevent the house circuit breaker on the public power supply system from tripping during the time phase in which the magnetic field of the coils of an electric motor has not yet been established.
CO detector according to DIN EN 50291
Item no.: 7549937Gas sensor GX-CO2-25
Item no.: 200989External, active CO2 sensor with its own alarm, LEDs and test button, for connection to the warning devices GX-A1+ or GX-HS, detects CO2 from used air or CO2 exhaled by people, as a timely reminder to ventilate at about half the MAC (2500 ppm).
Performance features
- External sensor for the gas detectors GX-A1 and GX-HS
- Mains operation also possible without warning device
- Detection of carbon dioxide(CO2): Reminder to ventilate regularly
Supply air damper electric ⌀ 100 mm
Item no.: 201756
The electric supply air damper with a diameter of 100 mm and a fast spring return motor opens within 8 seconds when the operating voltage is applied and closes, also braked by the spring gear, in about 8 seconds when the operating voltage is removed. Such a damper is controlled e.g. by the KZS 200 (301745) supply air control, which automatically opens the damper when the exhaust air motor is switched on.
Possible applications
- Supply air control for extractor bonnet
- For controlling the air flow in ventilation and air-conditioning systems
- Diameter: Ø100 mm
Prof. CO2 warning device for carbon dioxide GX-D500
Item no.: 300267
Possible applications
- for dispensing systems with carbon dioxide (CO2 carbon dioxide)
- according to DIN 6653-2
- Small to medium-sized breweries, wine and fermentation cellars
- Gastronomy with beverage dispensing equipment
- Dry ice storage and processing
- all plants with CO2 from pressure cylinders
WWD 100 Wireless Water Detector
Item no.: 200100Supply air damper electric ⌀ 200 mm
Item no.: 201752
The electric supply air damper with a diameter of 200 mm and a fast spring return motor opens within 8 seconds when the operating voltage is applied and closes, also braked by the spring gear, in about 8 seconds when the operating voltage is removed. Such a damper is controlled, for example, by the KZS 200 (301745) supply air control unit, which automatically opens the damper when the exhaust air motor is switched on.
Possible applications
- Supply air control for extractor bonnet
- For controlling the air flow in ventilation and air-conditioning systems
PROF. GAS ALARM GX-C300S
Item no.: 300265
The professional carbon monoxide warning device with internal CO sensor, whose measuring cell, evaluation electronics and software have been tested by TÜV Süd according to the standard, is here equipped with an additional external city and natural gas sensor, which makes the entire system the perfect warning device for the boiler room in which a gas heating system or boiler is installed. The alarm relay, which is energised in monitoring mode, drops out when gas is detected (methane, butane, propane, ethanol) or when the CO concentration specified by the standard is exceeded, and can thus switch off the heating system with its solenoid shut-off valve in the event of danger to reliably prevent further inflow of toxic or flammable gases.
CO2 ALARM GX-D1
Item no.: 300251The plug-in CO2 warning device with internal sensor for carbon dioxide is plugged into an upper (tolerant) or lower (sensitive) socket depending on the desired sensitivity, is ready for operation after 3 minutes preheating time and warns when half the MAC (2500 ppm) is reached with a loud alarm tone and red flashing LED.
Possible applications
- Monitoring of medical practices, waiting rooms, open-plan offices, workshops, etc.
- for all rooms where people spend long periods of time on a regular basis
- by the exclus. acoust. Warning ideal for waiting rooms or the like where a visual warning could irritate
- Reliable reminder to air regularly
Air flow monitor RLSW5
Item no.: 21006
The air flow monitor is placed in the exhaust air flow of a cooker hood behind the grease filter and monitors whether the exhaust air really flows at the required and adjustable speed. If this is the case, a potential-free changeover relay is switched, which releases the gas supply for gastronomic gas hobs by means of a gas solenoid shut-off valve. The air flow monitor is the basis for the so-called "mutual interlocking of exhaust air and gas supply".
Possible applications
- Use in gastronomy
- for mutual interlocking of the gas supply for ovens in combination with ventilation systems as well as extractor bonnets
GAS ALARM GX-B3
Item no.: 300222
The socket gas warning device with external sensor for town gas and natural gas is plugged into a socket and the sensor is set to an upper (natural gas / methane) or lower (liquid gas / butane, propane) position depending on the gas. The warning device is ready for operation after 3 minutes and warns already far below dangerous gas concentrations with an alarm tone and red flashing LED. In the event of an alarm, the appliance connected to the GX-B3, e.g. a gas heater, is also reliably switched off, whereby the appliance remains switched off until the user has ensured that his ventilation measures have had an effect and he resets it by briefly unplugging it and plugging it back into the socket.
Possible applications
- Monitoring of gas heating, gas cooker and pipes
- Detection of town, natural and liquid gases
- Control of a solenoid shut-off valve
Supply air damper electric ⌀ 150 mm
Item no.: 201755
The electric supply air damper with a diameter of 150 mm and a fast spring return motor opens within 8 seconds when the operating voltage is applied and closes, also braked by the spring gear, in about 8 seconds when the operating voltage is removed. Such a damper is controlled, for example, by the KZS 200 (301745) supply air control unit, which automatically opens the damper when the exhaust air motor is switched on.
Possible applications
- Supply air control for extractor bonnet
- For controlling the air flow in ventilation and air-conditioning systems
airtight supply air damper ⌀ 100 mm
Item no.: 201758
The airtight electric supply air damper with a diameter of 100 mm and a high-torque condenser motor opens and closes each time within 150 seconds during open-close control or via 2-way control. The relatively long time is due to the slow-running motor, which has to press the EPDM sealing lip against the galvanized steel pipe with a lot of force. Such a damper is controlled, for example, by the KZS 200 supply air control, which automatically opens the damper when the exhaust air motor is switched on.
Possible applications
- Supply air control for incinerators
- For controlling the air flow in ventilation and air-conditioning systems
- Diameter: 100 mm
Float switch
Item no.: 200983Reed contact switch (NC contact) SHT 3002
Item no.: 300770
The universally applicable magnetic switch with opener function can be used in all dry indoor spaces and, with its enclosed 4 spacer plates for height compensation, is ideal for mounting on door and window frames as well as door and window sashes. The 10-watt reed contact, which can be loaded with up to 500 mA at up to 20 volts, opens the contact when the magnet is very close to the switch. Without cable break protection, this switch cannot be used as an extension for Schabus exhaust air and air conditioning controls.
Possible applications
- Door / window switch with height compensation
- Monitoring switches for alarm systems, limit switches, model making, etc.
- LED interior lighting for wardrobe, like "fridge light" with opener contact
Water sensor SHT 5090
Item no.: 300721SHT 450 water detector with sensor cable
Item no.: 300450
No matter where ...
whether kitchen base cabinets, laundry rooms, bathroom furniture or the aquarium in the living room:
the SHT 450 detects water leaks everywhere with its sensor line and alerts you before worse damage occurs.
The 2 meter long sensor cable (extendable on request), reacts sensitively to single drops of water along its entire length. The mechanically strong cable, resistant to corrosion and abrasion, consists of two sensor wires embedded in a fluoropolymer carrier rod. Due to the robust cable construction with conductive polymer technology and fluoropolymer construction detection, no metal is exposed. For cleaning, you can wipe it with a clean damp cloth.
For connection to the Schabus water detectors is suitable only a LiYY control line with 2x 0.14mm², which can be ordered separately.
Possible applications
- Water ingress
- 100% made in Germany
- for laying under kitchen and bathroom furniture
- under aquariums
- under other devices, where water can leak over a wide area
- under pipes, tubs, tanks ...
- for indoor projects such as data centers / control rooms / HVAC / IOT
- Cistern monitoring
- Level monitoring
Gas sensor GX-LNG
Item no.: 300897PROF. CO ALARM GX-C330
Item no.: 300330
The CO ALARM GX-C330 is a carbon monoxide warning device for monitoring indoor areas with open combustion and is equipped with an integrated electro-chemical sensor. An LCD display constantly informs about the operating status as well as the exact measured ppm number of the CO concentration in the ambient air.Possible applications
Possible applications
- Shisha bars and smoking clubs
- Monitoring the proper functioning of ventilation systems
- Laboratory environments in universities, schools and companies
- Occupational safety measures for open burns in the catering industry
- Storage of CO in pressure cylinders
GX-D250
Item no.: 300253
Professional CO2 warning device for fixed installation with low warning levels from 800 ppm, which is intended to encourage regular ventilation of a room and supports this with discreet warning tones. Similar to a CO2 traffic light, the illuminated plain text display provides information on the interpretation of the warning levels in German, e.g. from 800 ppm "Please ventilate" and from 2000 ppm a potential-free changeover relay switches, e.g. to activate forced ventilation. The CO2 sensor is designed externally to find the optimal level independent of the position of the warning device.
Anti-theft device for CO2 traffic lights
Item no.: 300948Gas sensor GX-DS Carbon dioxide
Item no.: 200884Differential pressure controller DS01 M
Item no.: 21100DS-01 L Comfort package ventilation + stove
Item no.: 21021
The DS 01 L Comfort package already contains all accessories together with the DS 01 L control unit that are absolutely necessary for technical operation. In addition to the control unit and 5 metres of silicone hose, it contains the temperature measuring adapter, the pressure measuring adapter and the pressure measuring tube, which is intended for connecting the hose to the pressure measuring adapter. This way, nothing important can be forgotten with only one item number.
Possible applications
- For mutual safety monitoring (including interlocking) of ovens in combination with ventilation and air-conditioning systems such as controlled ventilation and extraction systems and extractor bonnets
- Ideal for the use of fireplaces (solid or liquid fuels) in low-energy or passive houses with ventilation systems (not suitable for open fireplaces or open operation).
Wall-mounted box Alu-Compound
Item no.: 21005Reed contact switch (NO contact) SHT 3001
Item no.: 300760This normally open reed contact switch with magnet is universal for various applications. The kit is attached to a door or window by simple mounting. The supplied spacer plates can be used for height compensation. A standard cable (LIYY 2x0,14mm²) is connected to the terminal and can be inserted from both sides. This allows a series connection of several contact switches.
This reed contact switch (normally open) is universal for various applications applicable!
Possible applications
- Door/window switch
- Monitoring switch
- Limit switch
- Model making
- uvm.
Gas Alarm GX-HS
Item no.: 400200WWD 150 Wireless Water Detector float switch
Item no.: 200150Mini float switch plastic changeover contact
Item no.: 200938airtight supply air damper ⌀ 150 mm
Item no.: 201760
The airtight electric supply air damper with a diameter of 150 mm and a high-torque condenser motor opens and closes each time within 150 seconds during open-close control or via 2-way control. The relatively long time is due to the slow-running motor, which has to press the EPDM sealing lip against the galvanized steel pipe with a lot of force. Such a damper is controlled, for example, by the KZS 200 supply air control, which automatically opens the damper when the exhaust air motor is switched on.
Possible applications
- Supply air control for incinerators
- For controlling the air flow in ventilation and air-conditioning systems
- Diameter: 150 mm
Reed contact switch (change-over contact) SHT 3030
Item no.: 300772Water detector SHT 218
Item no.: 300218
The SHT 218 socket water detector functions as a pump control. If soil moisture is detected with the sensor, the socket switches on the connected pump and the LED visually indicates the water ingress. After the sensor has dried, the pump continues to run for an adjustable follow-up time of 0 to 100 seconds and is then switched off.
Key switch
Item no.: 300776Cable H07RN-F 3×2,5mm² Titanex
Item no.: 05.06406.0Cable exhaust control KGS 116
Item no.: 300715
The KGS 116 cable gas heater control unit interrogates the potential-free normally open contact of a gas heater and converts the change of state of the gas heater into a changeover of the potential-free changeover relay. With this system, e.g. a bathroom fan can be switched off when the gas heater is ignited.
Possible applications
- Gas boiler in combination with bathroom fan
Pressure measuring tube accessories DS01 L
Item no.: 21004Pressure measuring adapter accessories DS01
Item no.: 21003GAS ALARM GX-D3
Item no.: 300233Mini float switch V4A normally open contact
Item no.: 300941
Stainless steel mini float switch for our water detectors SHT 5000, SHT 5001 and SHT 5002 with reed contact (25 V AC / 60 V DC / max. 0.5 A / max. 10 W) for food, water and many other liquid media from 0.7 g / cm³, to which stainless steel is resistant. Encapsulated with a 2.5 metre long LiYY cable.
Mini float switch V2A changeover contact
Item no.: 200939Exhaust gas temperature monitor ATW 519 50°C
Item no.: 201759
The Cetrotec exhaust gas temperature monitor type 519 with 50°C switching point is type-tested by TÜV, approved for use in heat generating plants and is mounted with a flange on a free piece of stove pipe with a minimum diameter of 120 mm. Its normally closed contact can switch power, its normally open contact is only intended for control tasks, so it is technically suitable for bridging an exhaust air control when the furnace is cold or is used slightly modified as a control device for our cable exhaust air controls.
Hint: Involve your chimney sweep in your planning before installation so that nothing stands in the way of acceptance afterwards. There are significant regional differences over which Elektrotechnik Schabus has no influence.
Possible applications
- Bivalent operation with gas or oil heating to lock it when the solid fuel boiler is in operation
- Monitoring tasks to switch off the exhaust air system in rooms with open or closed fireplaces to prevent exhaust gases from being sucked back into the rooms when the fireplace is burning.
- Other monitoring and control tasks such as controlling the storage tank charging pump
- Indicator lamp for fuel boiler burnout
airtight supply air damper ⌀ 200 mm
Item no.: 201761
The airtight electric supply air damper with a diameter of 150 mm and a high-torque condenser motor opens and closes each time within 150 seconds during open-close control or via 2-way control. The relatively long time is due to the slow-running motor, which has to press the EPDM sealing lip against the galvanized steel pipe with a lot of force. Such a damper is controlled, for example, by the KZS 200 supply air control, which automatically opens the damper when the exhaust air motor is switched on.
Possible applications
- Supply air control for incinerators
- For controlling the air flow in ventilation and air-conditioning systems
- Diameter: 200 mm
USB calibration adapter
Item no.: 200340Emergency power supply for GD-04K
Item no.: 200579GX-K1 Gas alarm with internal sensor
Item no.: 300931
The warning device warns of the toxic vapors that could escape from leaking refrigeration and cooling systems and primarily serves to protect people who should not inhale these vapors. The HFC ALARM GX-K1 with internal sensor or GX-K2 with external sensor already warns at concentrations far below a life-threatening level. This monitoring system is therefore set very sensitive according to its purpose.
The GX-K1 or GX-K2 is plugged into the sockets, with the GX-K2 the sensor is positioned appropriately and then the HFC warning device is ready for operation after 3 minutes preheating time and warns early in case of leakage at the cooling system with a loud alarm tone and red flashing LED. The device is suitable for normal household use and must not be used in potentially explosive atmospheres.
The warning device is ready for operation after 3 minutes of preheating time and gives early warning of leaks in the cooling system with a loud alarm tone and red flashing LED.
Possible applications
- Heat pumps
- Air conditioners
- Coolant and refrigerant
- Hydrofluorocarbon
CO2 traffic light "Factory
Item no.: 400360
Reminds of regular draught ventilation in case of stale air
Warning levels:
- at 1400 ppm CO2 on yellow
- from 2000 ppm CO2 on red
- from 2500 ppm CO2 on red flashing with alarm tone
- Monitoring of open-plan offices, production facilities, workshops, etc.
- for all rooms where people spend long periods of time on a regular basis
- Reliable reminder for regular draught ventilation
Water sensor SHT 5007 UV-stabilised
Item no.: 300754
Accessories for water detector
The water sensor SHT 5007 with 2 nickel-plated brass contacts and 6 meter cable is identical in construction to the SHT 5006 water sensor, except that here a particularly UV-stable plastic is used for overmolding, which prevents the sensor from becoming porous so quickly in outdoor areas and regular exposure to sunlight. The SHT 5007 sensor for connection to all Schabus water detectors is only suitable for regularly dry environments, ideal for detecting creeping moisture on floors and surfaces, but rather unsuitable for detecting water levels in shafts, tanks and other containers with regularly damp environments.