GX-D250
Item no.: 300253
Professional CO2 warning device for fixed installation with low warning levels from 800 ppm, which is intended to encourage regular ventilation of a room and supports this with discreet warning tones. Similar to a CO2 traffic light, the illuminated plain text display provides information on the interpretation of the warning levels in German, e.g. from 800 ppm "Please ventilate" and from 2000 ppm a potential-free changeover relay switches, e.g. to activate forced ventilation. The CO2 sensor is designed externally to find the optimal level independent of the position of the warning device.
Rosette - ⌀ 150 mm black - Accessories DS01
Item no.: 21011Supply air damper electric ⌀ 100 mm
Item no.: 201756
The electric supply air damper with a diameter of 100 mm and a fast spring return motor opens within 8 seconds when the operating voltage is applied and closes, also braked by the spring gear, in about 8 seconds when the operating voltage is removed. Such a damper is controlled e.g. by the KZS 200 (301745) supply air control, which automatically opens the damper when the exhaust air motor is switched on.
Possible applications
- Supply air control for extractor bonnet
- For controlling the air flow in ventilation and air-conditioning systems
- Diameter: Ø100 mm
Extension cable Schuko 3×2,5mm 30m
Item no.: 300230Rosette - ⌀ 150 mm silver gray - accessory DS01
Item no.: 21012Rosette - ⌀ 130 mm black - Accessories DS01
Item no.: 21009Rosette - ⌀ 130 mm silver gray - Accessories DS01
Item no.: 21010Supply air damper electric ⌀ 150 mm
Item no.: 201755
The electric supply air damper with a diameter of 150 mm and a fast spring return motor opens within 8 seconds when the operating voltage is applied and closes, also braked by the spring gear, in about 8 seconds when the operating voltage is removed. Such a damper is controlled, for example, by the KZS 200 (301745) supply air control unit, which automatically opens the damper when the exhaust air motor is switched on.
Possible applications
- Supply air control for extractor bonnet
- For controlling the air flow in ventilation and air-conditioning systems
Supply air damper electric ⌀ 200 mm
Item no.: 201752
The electric supply air damper with a diameter of 200 mm and a fast spring return motor opens within 8 seconds when the operating voltage is applied and closes, also braked by the spring gear, in about 8 seconds when the operating voltage is removed. Such a damper is controlled, for example, by the KZS 200 (301745) supply air control unit, which automatically opens the damper when the exhaust air motor is switched on.
Possible applications
- Supply air control for extractor bonnet
- For controlling the air flow in ventilation and air-conditioning systems
Extension cable Schuko 3×1,5mm 40m
Item no.: 300140GAS ALARM GX-D3
Item no.: 300233GX-CO2-30 Carbon dioxide gas sensor
Item no.: 300315
Ext. CO2 sensor for carbon dioxide - from technical equipment
The external CO2 sensor with its own alarm transmitter, status LEDs and test button is optimized as an accessory for the SCHABUS gas warning devices GX-HS and GX-A1+ is oriented with its warning levels and protection class IP54 to the beverage dispensing system regulation.
Gas sensor GX-CO2-25
Item no.: 200989External, active CO2 sensor with its own alarm, LEDs and test button, for connection to the warning devices GX-A1+ or GX-HS, detects CO2 from used air or CO2 exhaled by people, as a timely reminder to ventilate at about half the MAC (2500 ppm).
Performance features
- External sensor for the gas detectors GX-A1 and GX-HS
- Mains operation also possible without warning device
- Detection of carbon dioxide(CO2): Reminder to ventilate regularly
Cable exhaust control with thermal switch KDT 210
Item no.: 300674
This package without DIBt approval includes a classic cable exhaust air control set KDS 210 consisting of a window solenoid switch with intermediate plug control unit and an exhaust gas temperature monitor ATW 519 with integrated cable breakage protection for a free piece of stove pipe that is accessible at any time, with all components already pre-assembled. Due to the additional temperature switch, the exhaust air system can be operated independently of the window position as long as the furnace is cold; opening the window is only necessary when the furnace is in operation.
Hint: Involve your chimney sweep in your planning before installation so that nothing stands in the way of acceptance afterwards. There are significant regional differences over which Elektrotechnik Schabus has no influence.
Possible applications
- Fume cupboard control
- Exhaust air control
CO detector 40 ppm
Item no.: 7639852CO2 traffic light OFFICE
Item no.: 400380
In the hectic office routine, it is often noticed too late - many different factors cause the proverbial "thick air".
Our oxygen supply continuously decreases and we become flabby and tired. Fresh air means more oxygen - thus more well-being and more performance.
The CO2 traffic light "office" helps you to ventilate in time, to ventilate for a sufficiently long time and thus to ventilate in a sensible energy-saving way. This way you feel fit again faster - and that is logically also healthier.
Possible applications
- Room air monitoring in the office according to EU standard EN 13779
- Individual office, reception offices, open plan office, meeting rooms and more.
- reliable reminder to ventilate regularly
CO2 traffic light "school
Item no.: 400250
The CO2 traffic light "school" with internal NDIR sensor is an indicator of the carbon dioxide content in the room air and provides a visual warning of increasingly poor air quality in indoor areas where many people frequently spend time and encourages regular draught ventilation.
The device is not approved for any other use than described above.
Extension cable Schuko 3×1,5mm 50m
Item no.: 300150GAS ALARM GX-A1+
Item no.: 300892
The universal gas warning device for surface-mounted fixed installation is suitable for different gases depending on the sensor. It provides the operating voltage required for the sensor, regulates the heating current required for some sensors and evaluates the sensor voltage returned by the sensor and displays it on its illuminated plain text display. Based on the different voltages, the GX-A1+ recognizes five different states, including the pre-alarm from 2.0 volts and the main alarm from 2.5 volts, at which not only the potential-free changeover relay assigned to the alarm switches, but the entire warning device makes itself clearly audiovisually noticeable with a loud alarm tone and flashing display lighting. There are sensors for city and natural gas, refrigerant (HFC) and carbon dioxide in two measuring ranges; for carbon monoxide a separate set GX-A1+CO is available, as the TÜV-tested CO sensors are addressed and evaluated differently.
Possible applications
- Detection of town, natural and liquid gases
- Methane, butane, propane, ethanol
- Gastronomy, CO2 bottles, dispensing systems
- Dry ice processing and storage
- Detection of refrigerants such as R-32, R-404a, R-410a, etc.
airtight supply air damper ⌀ 100 mm
Item no.: 201758
The airtight electric supply air damper with a diameter of 100 mm and a high-torque condenser motor opens and closes each time within 150 seconds during open-close control or via 2-way control. The relatively long time is due to the slow-running motor, which has to press the EPDM sealing lip against the galvanized steel pipe with a lot of force. Such a damper is controlled, for example, by the KZS 200 supply air control, which automatically opens the damper when the exhaust air motor is switched on.
Possible applications
- Supply air control for incinerators
- For controlling the air flow in ventilation and air-conditioning systems
- Diameter: 100 mm
CO detector according to DIN EN 50291
Item no.: 7549937airtight supply air damper ⌀ 150 mm
Item no.: 201760
The airtight electric supply air damper with a diameter of 150 mm and a high-torque condenser motor opens and closes each time within 150 seconds during open-close control or via 2-way control. The relatively long time is due to the slow-running motor, which has to press the EPDM sealing lip against the galvanized steel pipe with a lot of force. Such a damper is controlled, for example, by the KZS 200 supply air control, which automatically opens the damper when the exhaust air motor is switched on.
Possible applications
- Supply air control for incinerators
- For controlling the air flow in ventilation and air-conditioning systems
- Diameter: 150 mm
airtight supply air damper ⌀ 200 mm
Item no.: 201761
The airtight electric supply air damper with a diameter of 150 mm and a high-torque condenser motor opens and closes each time within 150 seconds during open-close control or via 2-way control. The relatively long time is due to the slow-running motor, which has to press the EPDM sealing lip against the galvanized steel pipe with a lot of force. Such a damper is controlled, for example, by the KZS 200 supply air control, which automatically opens the damper when the exhaust air motor is switched on.
Possible applications
- Supply air control for incinerators
- For controlling the air flow in ventilation and air-conditioning systems
- Diameter: 200 mm
Wall-mounted box Alu-Compound
Item no.: 21005PROFI CO ALARM GX-C300
Item no.: 300255
Professional carbon monoxide warning device for fixed installation with warning levels and alarm delay times as specified in the DIN EN 50291 standard. Display of the exact measured CO concentrations in ppm on an illuminated plain text display. In case of alarm and in case of technical faults detected by the device itself, one potential-free change-over relay each switches to activate e.g. forced ventilation or to inform the BMS. The internal electrochemical sensor has a service life of 6 to 10 years, depending on the ambient conditions, and can easily be replaced by Elektrotechnik Schabus at the factory.
CO2 traffic light "Medical
Item no.: 400350
The CO2 traffic light "medical" with wall mount and plug-in power supply is our most sensitive version, which already switches to yellow at 800 ppm CO2, from 1200 ppm CO2 to red and from 2000 ppm CO2 to red flashing with alarm tone. It is therefore ideally suited for monitoring rooms in which many people with special physiological restrictions are often present, e.g. waiting rooms in doctors' surgeries or senior residences.
Possible applications
- Surveillance of doctors' surgeries, hospitals, old people's homes, etc.
- for all rooms where people spend long periods of time on a regular basis
- Reliable reminder for regular draught ventilation
CO2 traffic light "Factory
Item no.: 400360
Reminds of regular draught ventilation in case of stale air
Warning levels:
- at 1400 ppm CO2 on yellow
- from 2000 ppm CO2 on red
- from 2500 ppm CO2 on red flashing with alarm tone
- Monitoring of open-plan offices, production facilities, workshops, etc.
- for all rooms where people spend long periods of time on a regular basis
- Reliable reminder for regular draught ventilation
Comfort package FTW 519 with FDS 100 set
Item no.: 300519
This comfort package without DIBt approval includes a classic FDS 100 exhaust air control set consisting of a radio window switch with intermediate plug receiver and an FTW exhaust gas temperature monitor with integrated transmitter for long, completely free (not jacketed) stove pipes at a minimum height of 80 cm (measured from the top of the stove). This means that for very infrequently used furnaces, a window does not always have to be opened every time the exhaust air system is used.
Hint: Involve your chimney sweep in your planning before ordering so that nothing stands in the way of acceptance afterwards. There are significant regional differences over which Elektrotechnik Schabus has no influence. Comfort package FDS 100 / FTX 519
Item no.: 300539This comfort package without DIBt approval includes a classic radio exhaust control set FDS 100 consisting of a window switch with built-in receiver and a radio exhaust temperature monitor FTX with remote transmitter for shorter or covered, but always freely accessible stovepipes. This means that for very rarely used stoves, a window does not always have to be opened every time the exhaust air system is used.
Hint: Involve your chimney sweep in your planning before installation so that nothing stands in the way of acceptance afterwards. There are significant regional differences, on which Elektrotechnik Schabus has no influence.
FTW 519 Comfort package with FDS 200 set
Item no.: 300529
This comfort package without DIBt approval includes a classic FDS 200 exhaust air control set consisting of a radio window switch with built-in receiver and an FTW exhaust gas temperature monitor with integrated transmitter for long, completely free (unjacketed) stovepipes at a minimum height of 80 cm (measured from the top edge of the stove). This means that for very rarely used furnaces, a window does not always have to be opened as well every time the exhaust air system is used.
Hint: Involve your chimney sweep in your planning before ordering so that nothing stands in the way of acceptance afterwards. There are significant regional differences over which Elektrotechnik Schabus has no influence. Wall unit glass decor panel "white
Item no.: 21015Comfort package FDS 200 / FTX 519
Item no.: 300549This comfort package without DIBt approval includes a classic FDS 200 extract air control set consisting of a radio window switch with intermediate plug receiver and an FTX flue gas temperature monitor with remote transmitter for shorter or covered but always freely accessible stovepipes. This means that for very rarely used stoves, a window does not always have to be opened every time the exhaust air system is used.
PROF. CO ALARM GX-C330
Item no.: 300330
The CO ALARM GX-C330 is a carbon monoxide warning device for monitoring indoor areas with open combustion and is equipped with an integrated electro-chemical sensor. An LCD display constantly informs about the operating status as well as the exact measured ppm number of the CO concentration in the ambient air.Possible applications
Possible applications
- Shisha bars and smoking clubs
- Monitoring the proper functioning of ventilation systems
- Laboratory environments in universities, schools and companies
- Occupational safety measures for open burns in the catering industry
- Storage of CO in pressure cylinders
CO2 traffic light "customized
Item no.: 400370Air flow monitor RLSW5
Item no.: 21006
The air flow monitor is placed in the exhaust air flow of a cooker hood behind the grease filter and monitors whether the exhaust air really flows at the required and adjustable speed. If this is the case, a potential-free changeover relay is switched, which releases the gas supply for gastronomic gas hobs by means of a gas solenoid shut-off valve. The air flow monitor is the basis for the so-called "mutual interlocking of exhaust air and gas supply".
Possible applications
- Use in gastronomy
- for mutual interlocking of the gas supply for ovens in combination with ventilation systems as well as extractor bonnets
PROF. GAS ALARM GX-C300S
Item no.: 300265
The professional carbon monoxide warning device with internal CO sensor, whose measuring cell, evaluation electronics and software have been tested by TÜV Süd according to the standard, is here equipped with an additional external city and natural gas sensor, which makes the entire system the perfect warning device for the boiler room in which a gas heating system or boiler is installed. The alarm relay, which is energised in monitoring mode, drops out when gas is detected (methane, butane, propane, ethanol) or when the CO concentration specified by the standard is exceeded, and can thus switch off the heating system with its solenoid shut-off valve in the event of danger to reliably prevent further inflow of toxic or flammable gases.
PROF. CO ALARM GX-C300P
Item no.: 300256Professional carbon monoxide warning device for permanent installation with warning levels and alarm delay times as specified in the DIN EN 50291 standard and suction device by means of a silicone hose to monitor thermally demanding rooms (e.g. gas-operated sauna). Display of the exact measured CO concentrations in ppm on an illuminated plain text display. In the event of an alarm and technical faults detected by the unit itself, a potential-free changeover relay switches in each case, e.g. to activate forced ventilation or to inform the BMS. The internal electrochemical sensor has a service life of 6 to 10 years, depending on the ambient conditions, and can easily be replaced by Elektrotechnik Schabus at the factory.
Prof. CO2 warning device for carbon dioxide GX-D500
Item no.: 300267
Possible applications
- for dispensing systems with carbon dioxide (CO2 carbon dioxide)
- according to DIN 6653-2
- Small to medium-sized breweries, wine and fermentation cellars
- Gastronomy with beverage dispensing equipment
- Dry ice storage and processing
- all plants with CO2 from pressure cylinders
GAS ALARM SET GX-A1+CO
Item no.: 300266
We have designed the GX-A1+CO set in such a way that it is possible to equip a professional carbon monoxide warning device with an external sensor, e.g. to position the warning device in front of the room to be monitored and the sensor in the room to be monitored in order to see from the outside whether the room is safe to enter.
The carbon monoxide concentration is evaluated and displayed with ppm accuracy. In the event of an alarm, a potential-free changeover relay switches and another relay switches in the event of technical faults detected by the warning device itself, such as a cable break or sensor failure, in order to inform the building control system.
Possible applications
- Carbon monoxide CO from incomplete combustion
- open fireplace, gas stoves, Swedish stoves
- Open fire, barbecue facilities, pellet bunker
GX-D500P
Item no.: 300263
Possible applications
- Dry ice processing/storage
- Beverage dispensing systems and greenhouses
- Meat and sausage cooling
- according to DIN 6653-2
- Automatic forced ventilation
- Rooms with very hot, cold, humid or dusty air or in ventilation systems with draughts
Level indicator SET
Item no.: 300782
Performance features
- The digital tank display of the current content quantity is optionally in litres, in centimetres of filling level or as a percentage.
- For various liquids: Heating oil, diesel, biodiesel, vegetable oil, palm oil, rapeseed oil, water, lubricating oils, AdBlue, etc.
- Up to 2 m water column / oil tanks up to 2.5 m height
EFM Focus Module
Item no.: 400209EFM PSU 200 Power Supply Wireless and DMX
Item no.: 400207EMY 100 motoryoke
Item no.: 400201Differential pressure controller DS01 L
Item no.: 21000
The differential pressure controller DS 01 is a safety device that enables the simultaneous operation of room-air dependent fireplaces for solid or liquid fuels with ventilation systems.
Possible applications
- For mutual safety monitoring (including interlocking) of ovens in combination with ventilation and air-conditioning systems such as controlled ventilation and extraction systems and extractor bonnets
- Ideal for the use of fireplaces (solid or liquid fuels) in low-energy or passive houses with ventilation systems (not suitable for open fireplaces or open operation).
EPO retrofit kit PAN / TILT / PO module
Item no.: 400700EFM PSU 300 Power Supply Wireless and DMX
Item no.: 400208EPO retrofit kit set PAN / TILT / Focus / PO module
Item no.: 400710DS-01 L Comfort package ventilation + stove
Item no.: 21021
The DS 01 L Comfort package already contains all accessories together with the DS 01 L control unit that are absolutely necessary for technical operation. In addition to the control unit and 5 metres of silicone hose, it contains the temperature measuring adapter, the pressure measuring adapter and the pressure measuring tube, which is intended for connecting the hose to the pressure measuring adapter. This way, nothing important can be forgotten with only one item number.
Possible applications
- For mutual safety monitoring (including interlocking) of ovens in combination with ventilation and air-conditioning systems such as controlled ventilation and extraction systems and extractor bonnets
- Ideal for the use of fireplaces (solid or liquid fuels) in low-energy or passive houses with ventilation systems (not suitable for open fireplaces or open operation).
Differential pressure controller DS01 M
Item no.: 21100DS-01 L Comfort package ventilation + pellet primary stove
Item no.: 21022
The differential pressure controller DS 01 is a safety device that enables the simultaneous operation of room-air dependent fireplaces for solid or liquid fuels with ventilation systems.
Possible applications
- for monitoring the simultaneous operation of controlled ventilation systems and wodtke pellet primary stoves
- For mutual safety monitoring (including interlocking) of ovens in combination with ventilation and air-conditioning systems such as controlled ventilation and extraction systems and extractor bonnets
- Ideal for the use of fireplaces (solid or liquid fuels) in low-energy or passive houses with ventilation systems (not suitable for open fireplaces or open operation).