GX-CO2-30 Carbon dioxide gas sensor
Item no.: 300315
Ext. CO2 sensor for carbon dioxide - from technical equipment
The external CO2 sensor with its own alarm transmitter, status LEDs and test button is optimized as an accessory for the SCHABUS gas warning devices GX-HS and GX-A1+ is oriented with its warning levels and protection class IP54 to the beverage dispensing system regulation.
Cable exhaust control with thermal switch KDT 210
Item no.: 300674
This package without DIBt approval includes a classic cable exhaust air control set KDS 210 consisting of a window solenoid switch with intermediate plug control unit and an exhaust gas temperature monitor ATW 519 with integrated cable breakage protection for a free piece of stove pipe that is accessible at any time, with all components already pre-assembled. Due to the additional temperature switch, the exhaust air system can be operated independently of the window position as long as the furnace is cold; opening the window is only necessary when the furnace is in operation.
Hint: Involve your chimney sweep in your planning before installation so that nothing stands in the way of acceptance afterwards. There are significant regional differences over which Elektrotechnik Schabus has no influence.
Possible applications
- Fume cupboard control
- Exhaust air control
DS-01 M Comfort Package Multiple Occupancy
Item no.: 21024DS-01 M Comfort Package Mixed Occupancy
Item no.: 21023DS-01 L Comfort package ventilation + pellet primary stove
Item no.: 21022
The differential pressure controller DS 01 is a safety device that enables the simultaneous operation of room-air dependent fireplaces for solid or liquid fuels with ventilation systems.
Possible applications
- for monitoring the simultaneous operation of controlled ventilation systems and wodtke pellet primary stoves
- For mutual safety monitoring (including interlocking) of ovens in combination with ventilation and air-conditioning systems such as controlled ventilation and extraction systems and extractor bonnets
- Ideal for the use of fireplaces (solid or liquid fuels) in low-energy or passive houses with ventilation systems (not suitable for open fireplaces or open operation).
Differential pressure controller DS01 M
Item no.: 21100Wall unit glass decor panel "white
Item no.: 21015EMY motoryoke SET PSU 200 Focus
Item no.: 400610Special connection cable 4-core 5 metres
Item no.: 21013DS-01 L Comfort package ventilation + stove
Item no.: 21021
The DS 01 L Comfort package already contains all accessories together with the DS 01 L control unit that are absolutely necessary for technical operation. In addition to the control unit and 5 metres of silicone hose, it contains the temperature measuring adapter, the pressure measuring adapter and the pressure measuring tube, which is intended for connecting the hose to the pressure measuring adapter. This way, nothing important can be forgotten with only one item number.
Possible applications
- For mutual safety monitoring (including interlocking) of ovens in combination with ventilation and air-conditioning systems such as controlled ventilation and extraction systems and extractor bonnets
- Ideal for the use of fireplaces (solid or liquid fuels) in low-energy or passive houses with ventilation systems (not suitable for open fireplaces or open operation).
Folding float switch plastic
Item no.: 200949Reed contact switch (change-over contact) SHT 3030
Item no.: 300772airtight supply air damper ⌀ 100 mm
Item no.: 201758
The airtight electric supply air damper with a diameter of 100 mm and a high-torque condenser motor opens and closes each time within 150 seconds during open-close control or via 2-way control. The relatively long time is due to the slow-running motor, which has to press the EPDM sealing lip against the galvanized steel pipe with a lot of force. Such a damper is controlled, for example, by the KZS 200 supply air control, which automatically opens the damper when the exhaust air motor is switched on.
Possible applications
- Supply air control for incinerators
- For controlling the air flow in ventilation and air-conditioning systems
- Diameter: 100 mm
EYE Couplier clamp 50 mm
Item no.: 400336Rosette - ⌀ 150 mm silver gray - accessory DS01
Item no.: 21012Supply air damper electric ⌀ 100 mm
Item no.: 201756
The electric supply air damper with a diameter of 100 mm and a fast spring return motor opens within 8 seconds when the operating voltage is applied and closes, also braked by the spring gear, in about 8 seconds when the operating voltage is removed. Such a damper is controlled e.g. by the KZS 200 (301745) supply air control, which automatically opens the damper when the exhaust air motor is switched on.
Possible applications
- Supply air control for extractor bonnet
- For controlling the air flow in ventilation and air-conditioning systems
- Diameter: Ø100 mm
Water detector SHT 241
Item no.: 300241
The water detector for simple and quick installation!
The SHT 241 socket water detector functions as a purely acoustic detector. If a certain water level is detected with the mini float switch, a loud acoustic alarm sounds and the LED flashes red. After the water drops below the specified level, the device automatically goes silent and the LED turns green again.
Possible applications / special features:
- Same unit as SHT 240, but with float switch
- Particularly suitable for dirty water or other liquids (e.g. heating oil, diesel, vegetable oil, lubricating oil, etc.)
EFM Focus Module
Item no.: 400209EMY 100 motoryoke
Item no.: 400201Float switch
Item no.: 200983Wall-mounted box Alu-Compound
Item no.: 21005Cable air-conditioning control KKS 116
Item no.: 301750Cable air-conditioning control KKS 210
Item no.: 301672
The magnetic switch of the KKS 210 set monitors the window position and transmits the information via a thin wire to an intermediate plug control unit with a switched 5 A socket. In this way, an air conditioner can be switched off automatically when the window is tilted or open, so that the outside air is not cooled and energy is wasted unnecessarily.
Radio climate control FKS 200
Item no.: 301462
The transmitter of the FKS 200 set monitors the window position and transmits the information by radio to an adapter plug receiver with a switched 5 A socket. In this way, an air conditioner can be switched off automatically when a window is tilted or open, so that the outside air is not cooled and energy is wasted unnecessarily.
Key switch
Item no.: 300776Cable H07RN-F 3×2,5mm² Titanex
Item no.: 05.06406.0Control cable LIYY meter goods
Item no.: 300780Extension cable Schuko 3×1,5mm 10m
Item no.: 300110
This 10 meter long, flexible and highly durable extension cable is carefully handmade from the very best components such as the TITANEX cable 3x 1.5mm², ABL Sursum plug and coupling and each individually tested according to VDE by an expert in his field for highest insulation and lowest protective conductor resistance. This makes it extremely resilient, meets the highest demands and is virtually predestined for rough use in industrial operations, on construction sites or in event technology, i.e. in areas in which the application criteria are absolutely important and must be met exactly.
Possible applications
- Industrial enterprises
- public buildings
- Event technology
- Site equipment
- and much more.
Reed contact switch (NC contact) SHT 3020
Item no.: 300771Reed contact switch (NO contact) SHT 3010
Item no.: 300761
The universally applicable magnetic switch with normally open function can be used not only in dry interiors but also outdoors, i.e. on the outside of doors and windows.
Possible applications
- Door / window switch with height compensation
- Can also be used outdoors
- Monitoring switches for alarm systems, limit switches, model making, etc.
- LED interior lighting for wardrobe, like "fridge light" with opener contact
Reed contact switch (NC contact) SHT 3002
Item no.: 300770
The universally applicable magnetic switch with opener function can be used in all dry indoor spaces and, with its enclosed 4 spacer plates for height compensation, is ideal for mounting on door and window frames as well as door and window sashes. The 10-watt reed contact, which can be loaded with up to 500 mA at up to 20 volts, opens the contact when the magnet is very close to the switch. Without cable break protection, this switch cannot be used as an extension for Schabus exhaust air and air conditioning controls.
Possible applications
- Door / window switch with height compensation
- Monitoring switches for alarm systems, limit switches, model making, etc.
- LED interior lighting for wardrobe, like "fridge light" with opener contact
Reed contact switch (NO contact) SHT 3001
Item no.: 300760This normally open reed contact switch with magnet is universal for various applications. The kit is attached to a door or window by simple mounting. The supplied spacer plates can be used for height compensation. A standard cable (LIYY 2x0,14mm²) is connected to the terminal and can be inserted from both sides. This allows a series connection of several contact switches.
This reed contact switch (normally open) is universal for various applications applicable!
Possible applications
- Door/window switch
- Monitoring switch
- Limit switch
- Model making
- uvm.
Air flow monitor RLSW5
Item no.: 21006
The air flow monitor is placed in the exhaust air flow of a cooker hood behind the grease filter and monitors whether the exhaust air really flows at the required and adjustable speed. If this is the case, a potential-free changeover relay is switched, which releases the gas supply for gastronomic gas hobs by means of a gas solenoid shut-off valve. The air flow monitor is the basis for the so-called "mutual interlocking of exhaust air and gas supply".
Possible applications
- Use in gastronomy
- for mutual interlocking of the gas supply for ovens in combination with ventilation systems as well as extractor bonnets
Exhaust gas temperature monitor ATW 519 40°C
Item no.: 201749
The Cetrotec exhaust gas temperature monitor type 519 with 40°C switching point is type-tested by TÜV, approved for use in heat generating plants and is mounted with a flange on a free piece of stove pipe with a minimum diameter of 120 mm. Its normally closed contact can switch power, its normally open contact is only intended for control tasks, so it is technically suitable for bridging an exhaust air control when the furnace is cold or is used slightly modified as a control device for our cable exhaust air controls.
Possible applications
- Bivalent operation with gas or oil heating to lock it when the solid fuel boiler is in operation
- Monitoring tasks to switch off the exhaust air system in rooms with open or closed fireplaces to prevent exhaust gases from being sucked back into the rooms when the fireplace is burning.
- Other monitoring and control tasks such as controlling the storage tank charging pump
- Indicator lamp for fuel boiler burnout
GAS ALARM GX-B3
Item no.: 300222
The socket gas warning device with external sensor for town gas and natural gas is plugged into a socket and the sensor is set to an upper (natural gas / methane) or lower (liquid gas / butane, propane) position depending on the gas. The warning device is ready for operation after 3 minutes and warns already far below dangerous gas concentrations with an alarm tone and red flashing LED. In the event of an alarm, the appliance connected to the GX-B3, e.g. a gas heater, is also reliably switched off, whereby the appliance remains switched off until the user has ensured that his ventilation measures have had an effect and he resets it by briefly unplugging it and plugging it back into the socket.
Possible applications
- Monitoring of gas heating, gas cooker and pipes
- Detection of town, natural and liquid gases
- Control of a solenoid shut-off valve
Cable exhaust control KGS 116
Item no.: 300715
The KGS 116 cable gas heater control unit interrogates the potential-free normally open contact of a gas heater and converts the change of state of the gas heater into a changeover of the potential-free changeover relay. With this system, e.g. a bathroom fan can be switched off when the gas heater is ignited.
Possible applications
- Gas boiler in combination with bathroom fan
Cable supply air control KZS 200
Item no.: 301745
The intermediate plug of the cable supply air control KZS 200 is plugged in between the cooker hood and the socket and detects whether only the light of the hood or also the exhaust air motor is switched on by means of a consumption value adjustable from 5 to 250 watts. If the device detects a running motor, a supply air flap is opened via the line and also closed again after the exhaust air motor is switched off. The KZS 200 control unit is available for both variants of the Supply air dampers suitable for the slow but powerful Belimo motor of the airtight dampers as well as for the fast spring-return motor of the plastic dampers.
Possible applications
Hint:
Involve your chimney sweep in your planning before installation so that nothing stands in the way of acceptance afterwards. There are significant regional differences over which Elektrotechnik Schabus has no influence.
- Extractor fan control (independent of lighting)
- Supply air dampers
Pressure measuring tube accessories DS01 L
Item no.: 21004Pressure measuring adapter accessories DS01
Item no.: 21003Differential pressure controller DS01 L
Item no.: 21000
The differential pressure controller DS 01 is a safety device that enables the simultaneous operation of room-air dependent fireplaces for solid or liquid fuels with ventilation systems.
Possible applications
- For mutual safety monitoring (including interlocking) of ovens in combination with ventilation and air-conditioning systems such as controlled ventilation and extraction systems and extractor bonnets
- Ideal for the use of fireplaces (solid or liquid fuels) in low-energy or passive houses with ventilation systems (not suitable for open fireplaces or open operation).
Cable exhaust control KDS 210 DIBt
Item no.: 300672
The magnetic switch of the KDS 210 set with DIBt approval monitors the window position and transmits the information via a thin cable to an intermediate plug control unit with a switched 5 A socket. In this way, an exhaust air system can only be operated with a tilted or open window if it is ensured that sufficient fresh air flows into the room and thus no negative pressure is created that could draw dangerous and toxic carbon monoxide from a combustion site.
Possible applications
- Fume cupboard control
- Exhaust air control
- for trough fans is only KDS 110 suitable
Cable exhaust control KDS 116
Item no.: 300750
Cable exhaust control with built-in unit!
The magnetic switch of the KDS 116 without DIBt approval monitors the window position and transmits the information via a thin cable to a built-in control unit with potential-free 16 A changeover relay. For example, an exhaust air laundry dryer can only be operated with the window tilted or open if it is ensured that sufficient fresh air flows into the room and thus no negative pressure is created that could draw dangerous and toxic carbon monoxide from a combustion site.
Possible applications
- Fume cupboard control
- Bathroom fan control
- Exhaust air clothes dryer