Radio exhaust air control FDS 100 DIBt
Item no.: 300268
The transmitter of the FDS 100 set with DIBt approval monitors the window position and transmits the information by radio to a built-in receiver with a potential-free 5 A changeover relay. In this way, an exhaust air system can only be operated with a tilted or open window if it is ensured that sufficient fresh air flows into the room and thus no negative pressure is created that could draw dangerous and toxic carbon monoxide from a combustion site.
Radio exhaust air control FDS 200 DIBt
Item no.: 300462
Possible applications
The transmitter of the FDS 200 set with DIBt approval monitors the window position and transmits the information by radio to an intermediate plug receiver with a switched 5 A socket. In this way, an exhaust air system can only be operated with a tilted or open window if it is ensured that sufficient fresh air flows into the room and thus no negative pressure is created that could draw dangerous and toxic carbon monoxide from a combustion site.
Gas sensor GX-H2
Item no.: 200616Starting current limiter ASB 116 2500W/10A
Item no.: 300116GX-K2 Gas alarm with external sensor
Item no.: 300932
The warning device warns of the toxic vapors that could escape from leaking refrigeration and cooling systems and primarily serves to protect people who should not inhale these vapors. The HFC ALARM GX-K1 with internal sensor or GX-K2 with external sensor already warns at concentrations far below a life-threatening level. This monitoring system is therefore set very sensitive according to its purpose.
The GX-K1 or GX-K2 is plugged into the sockets, with the GX-K2 the sensor is positioned appropriately and then the HFC warning device is ready for operation after 3 minutes preheating time and warns early in case of leakage at the cooling system with a loud alarm tone and red flashing LED. The device is suitable for normal household use and must not be used in potentially explosive atmospheres.
The warning device is ready for operation after 3 minutes of preheating time and gives early warning of leaks in the cooling system with a loud alarm tone and red flashing LED.
Possible applications
- Heat pumps
- Air conditioners
- Coolant and refrigerant
- Hydrofluorocarbon
GX-D11
Item no.: 400311
The plug-in CO2 traffic light with internal NDIR sensor, the LED displays red, yellow and green, as well as discreet acoustic support, is used in areas where a reminder for regular ventilation is necessary, but people present should not be unsettled by yellow and red warning colours that are visible from afar.
GAS ALARM GX-D2
Item no.: 300252The plug-in CO2 warning device with external sensor for carbon dioxide is simply plugged into a socket and the sensor is placed in an upper (more tolerant) or lower (more sensitive) position depending on the desired sensitivity. It is ready for operation after 3 minutes of preheating time and warns when half the MAC (2500 ppm) is reached with a loud alarm tone and red flashing LED.
CO2 ALARM GX-D1
Item no.: 300251The plug-in CO2 warning device with internal sensor for carbon dioxide is plugged into an upper (tolerant) or lower (sensitive) socket depending on the desired sensitivity, is ready for operation after 3 minutes preheating time and warns when half the MAC (2500 ppm) is reached with a loud alarm tone and red flashing LED.
Possible applications
- Monitoring of medical practices, waiting rooms, open-plan offices, workshops, etc.
- for all rooms where people spend long periods of time on a regular basis
- by the exclus. acoust. Warning ideal for waiting rooms or the like where a visual warning could irritate
- Reliable reminder to air regularly
Flue gas temperature monitor ATW 519 - KDS 110/116
Item no.: 201753The Cetrotec flue gas temperature monitor type 519 with 40°C switching point and 10-k resistor is approved for use in heat generating plants and is mounted with a flange on a free piece of furnace pipe with a minimum diameter of 120 mm. Its normally open contact is only intended for control tasks and has been bridged by us with a 10 kOhm cable breakage protection resistor, therefore this version of the temperature monitor is only suitable as an optional accessory for our KDS cable exhaust air controls in order to enable an exhaust air system when the stove is cold without having to open a window each time as well, provided that the approval of the master chimney sweep is available, since an exhaust air control in combination with an exhaust gas temperature monitor does not have DIBt approval.
Cable supply air control KZS 200
Item no.: 301745
The intermediate plug of the cable supply air control KZS 200 is plugged in between the cooker hood and the socket and detects whether only the light of the hood or also the exhaust air motor is switched on by means of a consumption value adjustable from 5 to 250 watts. If the device detects a running motor, a supply air flap is opened via the line and also closed again after the exhaust air motor is switched off. The KZS 200 control unit is available for both variants of the Supply air dampers suitable for the slow but powerful Belimo motor of the airtight dampers as well as for the fast spring-return motor of the plastic dampers.
Possible applications
Hint:
Involve your chimney sweep in your planning before installation so that nothing stands in the way of acceptance afterwards. There are significant regional differences over which Elektrotechnik Schabus has no influence.
- Extractor fan control (independent of lighting)
- Supply air dampers
Cable air-conditioning control KKS 210
Item no.: 301672
The magnetic switch of the KKS 210 set monitors the window position and transmits the information via a thin wire to an intermediate plug control unit with a switched 5 A socket. In this way, an air conditioner can be switched off automatically when the window is tilted or open, so that the outside air is not cooled and energy is wasted unnecessarily.
Extension cable Schuko 3×2,5mm 20m
Item no.: 300220Emergency power supply for GD-04K
Item no.: 200579Gas Alarm GX-HS
Item no.: 400200Exhaust gas temperature monitor ATW 519 50°C
Item no.: 201759
The Cetrotec exhaust gas temperature monitor type 519 with 50°C switching point is type-tested by TÜV, approved for use in heat generating plants and is mounted with a flange on a free piece of stove pipe with a minimum diameter of 120 mm. Its normally closed contact can switch power, its normally open contact is only intended for control tasks, so it is technically suitable for bridging an exhaust air control when the furnace is cold or is used slightly modified as a control device for our cable exhaust air controls.
Hint: Involve your chimney sweep in your planning before installation so that nothing stands in the way of acceptance afterwards. There are significant regional differences over which Elektrotechnik Schabus has no influence.
Possible applications
- Bivalent operation with gas or oil heating to lock it when the solid fuel boiler is in operation
- Monitoring tasks to switch off the exhaust air system in rooms with open or closed fireplaces to prevent exhaust gases from being sucked back into the rooms when the fireplace is burning.
- Other monitoring and control tasks such as controlling the storage tank charging pump
- Indicator lamp for fuel boiler burnout
GX-K1 Gas alarm with internal sensor
Item no.: 300931
The warning device warns of the toxic vapors that could escape from leaking refrigeration and cooling systems and primarily serves to protect people who should not inhale these vapors. The HFC ALARM GX-K1 with internal sensor or GX-K2 with external sensor already warns at concentrations far below a life-threatening level. This monitoring system is therefore set very sensitive according to its purpose.
The GX-K1 or GX-K2 is plugged into the sockets, with the GX-K2 the sensor is positioned appropriately and then the HFC warning device is ready for operation after 3 minutes preheating time and warns early in case of leakage at the cooling system with a loud alarm tone and red flashing LED. The device is suitable for normal household use and must not be used in potentially explosive atmospheres.
The warning device is ready for operation after 3 minutes of preheating time and gives early warning of leaks in the cooling system with a loud alarm tone and red flashing LED.
Possible applications
- Heat pumps
- Air conditioners
- Coolant and refrigerant
- Hydrofluorocarbon
GAS ALARM GX-CO-12
Item no.: 300712
Areas of application
- mobile use in camping vehicles and on ships
- Camper, caravan
- other recreational vehicles with gas cooking and cooling facilities
- boiler room with gas heating or boiler
Exhaust gas temperature monitor ATW 519 40°C
Item no.: 201749
The Cetrotec exhaust gas temperature monitor type 519 with 40°C switching point is type-tested by TÜV, approved for use in heat generating plants and is mounted with a flange on a free piece of stove pipe with a minimum diameter of 120 mm. Its normally closed contact can switch power, its normally open contact is only intended for control tasks, so it is technically suitable for bridging an exhaust air control when the furnace is cold or is used slightly modified as a control device for our cable exhaust air controls.
Possible applications
- Bivalent operation with gas or oil heating to lock it when the solid fuel boiler is in operation
- Monitoring tasks to switch off the exhaust air system in rooms with open or closed fireplaces to prevent exhaust gases from being sucked back into the rooms when the fireplace is burning.
- Other monitoring and control tasks such as controlling the storage tank charging pump
- Indicator lamp for fuel boiler burnout
Water detector SHT 5000 12-24V
Item no.: 300790
SHT 5000 - the all-rounder among the water detectors - now optimized for the WWD 200 smart home adapterwhich sends you push notifications to your smartphone via the Smart Live app.
Areas of application
- Water ingress / water pipe burst
- Pump control
- Cistern monitoring
- Level monitoring
- Overflow message (e.g. drainage shaft)
- Monitoring flat roofs
- Combined with mini float switch also suitable for other liquids (e.g. heating oil, diesel, vegetable oil, lubricating oils, etc.)
- Automatic bilge pumps (SHT5000-24 V for boats)
- for water sports, hobby brewers, aquariums, model making, swimming pools, bathrooms and kitchens, workshops, etc.
- IP 65 on request
Mini float switch V4A changeover contact
Item no.: 300939
Stainless steel mini float switch for our water detectors SHT 5000, SHT 5001 and SHT 5002 with reed contact (25 V AC / 60 V DC / max. 0.5 A / max. 10 W) for food, water and many other liquid media from 0.7 g / cm³, to which stainless steel is resistant. Encapsulated with a 2.5 metre long LiYY cable.
Cable exhaust control KDS 210 DIBt
Item no.: 300672
The magnetic switch of the KDS 210 set with DIBt approval monitors the window position and transmits the information via a thin cable to an intermediate plug control unit with a switched 5 A socket. In this way, an exhaust air system can only be operated with a tilted or open window if it is ensured that sufficient fresh air flows into the room and thus no negative pressure is created that could draw dangerous and toxic carbon monoxide from a combustion site.
Possible applications
- Fume cupboard control
- Exhaust air control
- for trough fans is only KDS 110 suitable
Water detector SHT 5000 230 VAC/50 Hz
Item no.: 300744
SHT 5000 - the all-rounder among the water detectors - now optimized for the WWD 200 smart home adapterwhich sends you push notifications to your smartphone via the Smart Live app.
Areas of application
- Water ingress / water pipe burst
- Pump control
- Cistern monitoring
- Level monitoring
- Overflow message (e.g. drainage shaft)
- Monitoring flat roofs
- Combined with mini float switch also suitable for other liquids (e.g. heating oil, diesel, vegetable oil, lubricating oils, etc.)
- Automatic bilge pumps (SHT5000-24 V for boats)
- for water sports, hobby brewers, aquariums, model making, swimming pools, bathrooms and kitchens, workshops, etc.
- IP 65 on request
GAS ALARM GX-B2pro
Item no.: 300926
The socket gas warning device with external sensor for town gas and natural gas is plugged into a socket and the sensor is set to an upper (natural gas / methane) or lower (liquid gas / butane, propane) position depending on the gas. The warning device is ready for operation after 3 minutes of preheating time and warns already far below dangerous gas concentrations with a loud alarm tone and red flashing LED.
Possible applications
- Monitoring of gas heating or gas cooker / detection of town, natural and liquid gases
- Monitoring of the heating and utility rooms
- Storage of liquid gas cylinders or camping gas
- Air conditioners / coolants
Gas sensor GX-CFC for refrigerant
Item no.: 200901Extension cable Schuko 3×1,5mm 20m
Item no.: 300120Water detector SHT 5001
Item no.: 400748
The SHT 5001 water detector for top-hat rail mounting in the fuse box or small distribution board has 2 independent detection lines, which are designed identically with the option of connecting sensors or mini float switches to their own inputs in each case, activating the alarm memory via wire jumper or switching a potential-free changeover relay when "water" is detected. Test, reset, internal alarm beeper, or the connection of external alarm indicators with 12 volts to 30 mA, on the other hand, are carried out together for both detection lines. The cable lengths can be extended for sensors up to 100 meters, for mini-float switches up to 300 meters per signal line, provided that only thin and unshielded 2x0.14mm² LiYY cables are used, which are not laid parallel to lines of the mains AC voltage.
GAS ALARM GX-B1pro
Item no.: 300924
The socket gas warning device with internal sensor for town gas and natural gas is plugged into an upper (natural gas / methane) or lower (liquid gas / butane, propane) socket depending on the gas, is ready for operation after 3 minutes preheating time and warns already far below dangerous gas concentrations with a loud alarm tone and red flashing LED.
Possible applications
- Monitoring of gas heating or gas cooker / detection of town, natural and liquid gases
- Monitoring of the heating and utility rooms
- Storage of liquid gas cylinders or camping gas
- Air conditioners / coolants
CO GAS ALARM GX-C1pro
Item no.: 300783
The socket carbon monoxide warning device with internal electrochemical CO sensor is plugged into a medium-sized socket, is ready for operation after 5 minutes initialisation time and warns of excessive CO concentrations strictly according to the specifications of DIN EN 50291 for carbon monoxide in living spaces with a loud alarm tone and red flashing LED. The sensor, the evaluation, the measuring cell with its calibration as well as the software developed by Elektrotechnik Schabus were subjected to a full test at TÜV Süd according to DIN EN 50291, safety and stability were certified for the system.
Possible applications
- Monitoring for carbon monoxide leakage at combustion sites in flats, houses, shops, small businesses, cafés, low-dust workshops
- Monitoring of all gas-fired installations
- For gas heaters, gas heating, gas cookers, gas ovens, but also oil heaters and open fires, can also be used in bathrooms and other damp rooms, as long as moisture does not condense.
- Designed for years of continuous operation
Aqua Scanner SHT 5020
Item no.: 300746
The Aqua Scanner SHT 5020 is a 2 meter long sensor (extendable on request), sensitive to single drops of water along its entire length. The mechanically strong cable, resistant to corrosion and abrasion, consists of two sensor wires embedded in a fluoropolymer carrier rod. Due to the robust cable construction with conductive polymer technology and fluoropolymer construction detection, no metal is exposed. For cleaning, you can wipe it with a clean damp cloth.
For connection to the Schabus water detectors is suitable only a LiYY control line with 2x 0.14mm², which can be ordered separately.
Possible applications
- Accessories for SCHABUS water detectors SHT 5000, 5001 and 5002
- 100% made in Germany
- for laying under kitchen and bathroom furniture
- under aquariums
- under other devices, where water can leak over a wide area
- under pipes, tubs, tanks ...
- for indoor projects such as data centers / control rooms / HVAC / IOT
Water detector SHT 5002
Item no.: 300749
The SHT 5002 water detector for top-hat rail mounting in the fuse box or small distribution board is designed as a level controller and has 2 different detection lines. Detection line 1 is the actual level controller, which receives the functions "Fill" or "Drain" by means of a wire jumper and switches its potential-free 5 A changeover relay depending on a lower and an upper level, each of which is defined by a mini float switch. Detection line 2 works like a simple water detector and is called "overflow detector" here, i.e. as soon as water is detected by a sensor or mini-float switch, the second relay of the SHT 5002 switches over.
Water detector SHT 218
Item no.: 300218
The SHT 218 socket water detector functions as a pump control. If soil moisture is detected with the sensor, the socket switches on the connected pump and the LED visually indicates the water ingress. After the sensor has dried, the pump continues to run for an adjustable follow-up time of 0 to 100 seconds and is then switched off.
Aquastop SHT 226
Item no.: 300228
The Aquastop SHT 226 is a protection system with device shutdown. The electronic alarm and shutdown device detects the smallest amounts of liquid and switches off the connected device.
Possible applications
- Detection of water level changes (at least 4 cm)
- also for other liquids (e.g. fuel oil, diesel, vegetable oil, lubricating oil, etc.)
Mini float switch V4A normally open contact
Item no.: 300941
Stainless steel mini float switch for our water detectors SHT 5000, SHT 5001 and SHT 5002 with reed contact (25 V AC / 60 V DC / max. 0.5 A / max. 10 W) for food, water and many other liquid media from 0.7 g / cm³, to which stainless steel is resistant. Encapsulated with a 2.5 metre long LiYY cable.
SHT 450 water detector with sensor cable
Item no.: 300450
No matter where ...
whether kitchen base cabinets, laundry rooms, bathroom furniture or the aquarium in the living room:
the SHT 450 detects water leaks everywhere with its sensor line and alerts you before worse damage occurs.
The 2 meter long sensor cable (extendable on request), reacts sensitively to single drops of water along its entire length. The mechanically strong cable, resistant to corrosion and abrasion, consists of two sensor wires embedded in a fluoropolymer carrier rod. Due to the robust cable construction with conductive polymer technology and fluoropolymer construction detection, no metal is exposed. For cleaning, you can wipe it with a clean damp cloth.
For connection to the Schabus water detectors is suitable only a LiYY control line with 2x 0.14mm², which can be ordered separately.
Possible applications
- Water ingress
- 100% made in Germany
- for laying under kitchen and bathroom furniture
- under aquariums
- under other devices, where water can leak over a wide area
- under pipes, tubs, tanks ...
- for indoor projects such as data centers / control rooms / HVAC / IOT
- Cistern monitoring
- Level monitoring
Water detector SHT 228
Item no.: 300219
The water detector for pump control!
The SHT 228 socket water detector functions as a pump control. If a certain water level is detected with the mini float switch, the socket switches on the connected pump and in contrast to the SHT 227, the SHT 228 does not sound an alarm. After the water level drops below the specified level, the pump continues to run for an adjustable run-on time of 0 to 100 seconds and is then switched off.
Possible applications
- Water ingress
- Pump sump
- Cistern monitoring
- Also suitable for other liquids (e.g. heating oil, diesel, vegetable oil, lubricating oils, etc.)
Cable exhaust control KDS 110 DIBt
Item no.: 300740The magnetic switch of the KDS 110 set with DIBt approval monitors the window position and transmits the information via a thin cable to a built-in control unit with a potential-free 5 A change-over relay. In this way, an exhaust air system can only be operated with a tilted or open window if it is ensured that sufficient fresh air flows into the room and thus no negative pressure is created that could draw dangerous and toxic carbon monoxide from a combustion site. Depending on the connection option (e.g. Miele PUR 98), the light of the bonnet can also be switched on independently of the window position.
Water detector SHT 241
Item no.: 300241
The water detector for simple and quick installation!
The SHT 241 socket water detector functions as a purely acoustic detector. If a certain water level is detected with the mini float switch, a loud acoustic alarm sounds and the LED flashes red. After the water drops below the specified level, the device automatically goes silent and the LED turns green again.
Possible applications / special features:
- Same unit as SHT 240, but with float switch
- Particularly suitable for dirty water or other liquids (e.g. heating oil, diesel, vegetable oil, lubricating oil, etc.)
Water detector SHT 227 Pump control
Item no.: 300227
The water detector for pump control!
The SHT 227 socket water detector functions as a pump control. If a certain water level is detected with the mini float switch, the socket switches on the connected pump and an alarm sounds. After the water level drops below the specified level, the pump continues to run for an adjustable follow-up time of 0 to 100 seconds, is then switched off and the alarm stops again.
Possible applications
- Water ingress
- Pump sump
- Cistern monitoring
- Also suitable for other liquids (e.g. heating oil, diesel, vegetable oil, lubricating oils, etc.)
Gas sensor GX-LNG
Item no.: 300897Alarm Controller Ei450
Item no.: 200723
Radio alarm controller for smoke detectors and heat detectors and CO detectors!
Radio remote control of all CO, smoke and heat detectors from EiElectronics combined in a radio network, locating the triggering detector, common testing, muting and saving the last alarm triggers. Incl. 10-year lithium battery and practical wall bracket.
Gas sensor GX-SE City / natural gas
Item no.: 200897-SEGas sensor GX-CO
Item no.: 200898-COWWD 200 Smart Home Adapter
Item no.: 200200Ball protection grid for CO2 traffic light
Item no.: 300947Water detector SHT 217
Item no.: 300217
The SHT 217 socket water detector functions as a pump control. If the sensor detects soil moisture, the socket switches on the connected pump and an alarm sounds. After the sensor has dried, the pump continues to run for an adjustable follow-up time of 0 to 100 seconds, is then switched off and the alarm stops again.
Possible applications
- Water ingress
- Pump control
- Cistern monitoring
- Pump sump (dry)
Aquastop SHT 216
Item no.: 300260Water detector SHT 240
Item no.: 300240WWD 150 Wireless Water Detector float switch
Item no.: 200150Radio magnetic switch FDS 098 L
Item no.: 300198
Additional transmitter for a second window can be combined with the FDS 100, FDS 200 and FDS 216 devices. At least one window must be open for the exhaust air system to be switched on.
The serial number can be found on the type plate of the radio receiver or transmitter under the barcode field.
Longlife additional transmitter for FDS 100/200/216
Cable air-conditioning control KKS 116
Item no.: 301750Cable exhaust control KGS 116
Item no.: 300715
The KGS 116 cable gas heater control unit interrogates the potential-free normally open contact of a gas heater and converts the change of state of the gas heater into a changeover of the potential-free changeover relay. With this system, e.g. a bathroom fan can be switched off when the gas heater is ignited.
Possible applications
- Gas boiler in combination with bathroom fan
Cable exhaust control KDS 116
Item no.: 300750
Cable exhaust control with built-in unit!
The magnetic switch of the KDS 116 without DIBt approval monitors the window position and transmits the information via a thin cable to a built-in control unit with potential-free 16 A changeover relay. For example, an exhaust air laundry dryer can only be operated with the window tilted or open if it is ensured that sufficient fresh air flows into the room and thus no negative pressure is created that could draw dangerous and toxic carbon monoxide from a combustion site.
Possible applications
- Fume cupboard control
- Bathroom fan control
- Exhaust air clothes dryer
Extension cable Schuko 3×2,5mm 10m
Item no.: 300210Mini float switch V2A changeover contact
Item no.: 200939Water sensor SHT 5090
Item no.: 300721BBB 300 Potential-free contact | Light control
Item no.: 200603
The BBB300 add-on module turns a switched socket (e.g. KDS 210 and FDS 200 exhaust air controls) into a potential-free contact that can be loaded with up to 5 amps. Ideal for using the control contacts of newer exhaust systems with existing socket exhaust control, but also to switch off only the motor and leave the lighting untouched. The switching behavior is: socket switched on = contact closed.
WWD 100 Wireless Water Detector
Item no.: 200100Extension cable Schuko 3×1,5mm 10m
Item no.: 300110
This 10 meter long, flexible and highly durable extension cable is carefully handmade from the very best components such as the TITANEX cable 3x 1.5mm², ABL Sursum plug and coupling and each individually tested according to VDE by an expert in his field for highest insulation and lowest protective conductor resistance. This makes it extremely resilient, meets the highest demands and is virtually predestined for rough use in industrial operations, on construction sites or in event technology, i.e. in areas in which the application criteria are absolutely important and must be met exactly.
Possible applications
- Industrial enterprises
- public buildings
- Event technology
- Site equipment
- and much more.